A.3 Commands and Response
Appendix A-67
A.3.3.5
START command
When the scanner receives this command, the scanner reports the size of document being read.
Byte 1
CNT
Byte 2
CMD
Byte 3 and
later
X’02’
X’53’
-
A.3.3.6 READ command
When the scanner receives this command, the scanner starts reading based on the previously set
operation mode.
Issuing the response other than Read Complete during read operation causes error.
Byte 1
CNT
Byte 2
CMD
Byte 3 and
later
X’02’
X’54’
-
A.3.3.7 SENSE command
When the scanner receives this command, the scanner reports the scanner status.
The Sense command can be issued at any time if another command does not require the response
from the scanner.
Byte 1
CNT
Byte 2
CMD
Byte 3 and
later
X’02’
X’41’
-
A.3.3.8 RETURN SENSE command
By this command, the scanner reports that the carrier unit has come back to the home position.
Byte 1
CNT
Byte 2
CMD
Byte 3 and
later
X’02’
X’42’
-