Image Functions
3-8
Ex. Offset X1 = 0.5
″
= 200 (@1/400 inch) = X’C8’
Y1 = 0.6
″
= 240 (@1/400 inch) = X’F0’
Width X2 (main scanning direction) = 8.3
″
= 3,320 (@1/400 inch) = X’CF8’
Length Y2 (Sub-scanning direction) = 11.7
″
= 4,680 (@1/400 inch) = X’1248’
Output resolution = 600 dpi
The specification of X1 must be;
A#10 = X’00’
A#11 = X’C8’
The specification of X2must be;
A#12 = X’0C’
A#13 = X’F8’
The specification of Y1 must be;
A#14 = X’00’
A#15 = X’F0’
The specification of Y2must be;
A#16 = X’12’
A#17 = X’48’
As a result the output Main Window width and length may be rounded up as follows.
Width =
[
3320
----------
×
600
÷
8
400
]
= 622 bytes
Length =
[
4680
----------
×
600
400
]
= 7020 raster
* the value in [ ] are rounded up to integer