A.3 Commands and Response
Appendix A-61
Subwindow control register A#12
Subwindow control register B#12
*1
Subwindow control registers A#12/B#12 to A#14/B#14 must be sent in one sequence.
One of automatic separation, image emphasis, outline extract, overlay can be specified.
*2
When image area separation is specified, the density level for line drawing area follows the
subwindow control register A#10/B#10 or A#17/B#17, and the dither pattern for photo area follows
the subwindow control register A#11/B#11, and halftone processing for photo area follows
subwindow control register A#16/B#16.
X’00’ is set when the power is turned on or when the initial state is specified by the CLEAR command.
7
0
6
0
5
0
4
3
0
2
0
1
0
0
LSB
Automatic separation specification (*2)
0:
Not specified
1:
Specified
Black/white conversion mode specification
0:
Normal
1:
Reverse
(*1)