![OE Max Controls CSDP Plus Скачать руководство пользователя страница 95](http://html1.mh-extra.com/html/oe-max-controls/csdp-plus/csdp-plus_user-manual_3398524095.webp)
97
Please set the P control shift reference for a torque
command at SEt-55. The setting range is 0 to 300%
and the default value is 100.
Please set the P control shift reference for a speed
command at SEt-56. The setting range is 0 to 3000
RPM and the default value is 100.
Please set the P control shift reference for a
position error at SEt-57. The setting range is 0 to
10000 pulse and the default value is 100.
The picture below shows the speed response when the speed
regulator is changed from PI to P by torque command in the transient
response status.
In the transient status of acceleration area or deceleration area, if the
torque command is bigger than the P/PI mode shift reference, the
speed regulator will be P type and PI controller type in other areas.
Set Value
Function
0
Do not use P/PI mode shift.
1
Shifts when the torque command is bigger than P control shift reference
value (%).
2
Shifts when the speed command is bigger than P control shift reference
value (RPM).
3
Shifts when the position error is bigger than P control shift reference
(pulse).
ATTENTION
/P-CON signal will be shifted prior to P control shift switch
and the reference set-up. In other words, regardless of the
current motor status and the set-up of these values, the speed
regulator will be P controller type if /P-CON signal is ON.
To reduce the position completion time or overshoot of the
speed response by using this function, P control shift switch
and the reference should be set up properly. Please closely
watch transient responses of speed, torque, and position for
optimum set-up.
Содержание CSDP Plus
Страница 1: ...Maximum Value for OEMs SM CSDP Plus Servo Drive User Manual...
Страница 16: ...18...
Страница 21: ...23 The sizes of CSDP 15BX2 CSDP 20BX2 CSDP 30BX2 are as below The sizes of CSDP 40BX2 CSDP 50BX2 are as below...
Страница 30: ...32 Higher Control Connector CN1 Circuit Diagram...
Страница 33: ...35 Compact Absolute Encoder Wiring Serial Encoder Wiring...
Страница 36: ...38 Grounding Wiring Please separate the input and output wires of the filter and do not tie them together...
Страница 38: ...40...
Страница 120: ...122...
Страница 179: ...181 Speed Torque Curve...
Страница 180: ...182...
Страница 183: ...185 Speed Torque Curve...
Страница 184: ...186...
Страница 187: ...189...
Страница 190: ...192 Speed Torque Curve...
Страница 193: ...195...
Страница 196: ...198...
Страница 201: ...203...
Страница 204: ...206...
Страница 207: ...209...
Страница 210: ...212...
Страница 215: ...217...
Страница 230: ...232...
Страница 252: ...254...
Страница 253: ......