Appendix A
Parameter
SEt-01 Speed Command Gain
•
Setting range: 10 to 6000 RPM/1V, RPM/10V
•
User Default: 500
•
Changes anytime
The second digit of SEt-46 determines the preset unit of the parameter.
Speed command gain determines the gradient of the graph.
Speed command (RPM) = SEt-01 × Input Voltage (V)