161
Forward direction is counterclockwise when the motor is looked at
from the front. Reverse direction is clockwise when looked at from
the front.
SEt-46(1) Position Command Pulse Type
•
Setting range: 0 x 0 to 0 x 9
•
User Default: 0 x 0
•
Changes while the servo is OFF
The set values are as follows.
0: Positive Logic CW + CCW
1: Negative Logic CW + CCW
2: Positive Logic A Phase + B Phase 1 Multiplication
4: Positive Logic A Phase + B Phase 2 Multiplication
6: Positive Logic A Phase + B Phase 4 Multiplication
8: Positive Logic Sign + Pulse
9: Negative Logic Sign + Pulse
Positive Logic Pulse