82
Acceleration time is the time required for the motor to reach the rated
speed from standstill.
Please set the acceleration time at SEt-19. The
setting range is 0 to 60000 ms and the default value
is 200.
The diagram shows that the time for execution compared to command
was extended as much as the deceleration time.
Deceleration time is the time required for the motor to slow down to a
halt from the rated speed.
Please set deceleration time at SEt-20. The setting
range is 0 to 60000 ms and the default value is 200.