VOLTage:PROTection:CLEar
Command that disables OVP(Over voltage protection) Trip.
Before disable Trip, check reference "3-4. Programming Over Voltage Protection(OVP)" and fig
reason of tripping.
ex) volt:prot:cle
Clear OVP Trip
VOLTage:RANGe {LOW|HIGH}
Command that selects low range & high range of Dual Range Power Supply.
LOW
Select low range.
HIGH Select high range.
ex) volt:rang HIGH
Select high range
VOLTage:RANGe?
g
Command that check current selection of Dual Range Power Supply.
Return value "LOW" - Low Range Condition
"HIGH" - High Range Condition
ex) volt:rang?
return value "HIGH"
CURRent{<current>|UP|DOWN}
Able to set output current, instrument current will be set.
Control setting range before using UP, DOWN Command.
> current Input current value
> UP
Raise current setting value as step value
> DOWN
Decrease current setting value as step value
ex1) curr 4.5
Current 4.5A Setting
ex2) curr up
Raise as step value
After power on and *RST command, Current step value will be DEFAULT.
Read reference for Default value
Note
CURRent?
Check Power Supply's current setting.
Return value "current"
ex) curr?
return value "4.5000"
{
}
CURRent:STEP{<numeric value>}
Command that set step value that is used in CURR UP or CURR DOWN command.
> numeric value Input step value in selectable range
ex) curr:step 0.5
Set step value 0.5A
- 67 -