3-4. Programming Over Voltage Protection(OVP)
Disables Voltage when output voltage is higher than user set up.
Read below to set up OVP Level.
the OVP Level below can be diffierent from others
▌Power Switch On
▌Power Switch On
After turning on, check "
**OUTPUT OFF**
" is displayed on the screen.
▌Press OVP key to Level & Set up.
VFD Display Description
OVP ON
▌
In
"
OVP ON
" condition, press OVP button once more.
▌
In OVP ON
condition, press OVP button once more.
VFD Display Description
▌Change value using cursor keys.
▌Use encoder switch to change level value.
OVP-LEVEL 32.0V
▌When the setting is done, press OVP key.
VFD Display Description
Message will be Displayed and return to front page.
CHANGED
▌To cancel, press ESC key.
There is no cancelling message, return to front page.
▌To disable OVP, press OVP Key
VFD Display Description
OVP ON
▌
Press Left or Right cursor key while
"
OVP ON
" displayed.
VFD Display Description
▌
To save
"
OVP OFF
" press OVP Key.
VFD Display Description
OVP OFF
CHANGED
Message will be Displayed and return to front page.
▌To cancel, press ESC key.
There is no cancelling message, return to front page.
- 26 -