CYC:STEP:MODE:{STEP_NUM} {CC | CV | OFF }
Command for setting Mode and Step for cycling mode.
> STEP_NUM
Set step for cycling mode.
> CC
CC Mode Setting
> CV
CV Mode Setting
> OFF
OFF Mode Setting
ex1) CYC:STEP:MODE:1 CC
ex2) CYC:STEP:MODE:1 CV
ex3) CYC:STEP:MODE:1 OFF
CYC:STEP:MODE:{STEP_NUM}?
Command for checking mode that was saved in steps of cycling mode.
Return value
"mode"
ex) CYC:STEP:MODE:1?
return value "OFF"
CYC:STEP:VAL:{STEP_NUM} {VALUE}
Command for setting Step number and value.
> VALUE
Input value.
ex)CYC:STEP:VAL:1 10
Save 10 in step 1
CYC:STEP:VAL:{STEP_NUM}?
Return value
"VALUE"
ex) CYC:STEP:VAL:1?
return value "10.0"
CYC:STEP:SLOPE:{STEP_NUM} {1|2|3|4|5|6|7|8|9|10|11|12}
Command for setting slope for saving data.
> VALUE
Cycling SLOPE Value
ex)CYC:STEP:SLOPE:1 10 Save SLOPE 10 at STEP 1.
CYC:STEP:SLOPE:{STEP_NUM}?
Command for checking SLOPE that was saved in step.
Return value
"slope"
ex) CYC:STEP:SLOPE:1?
return value "10"
Command for checking step value that was saved in steps.
- 81 -