13. Left cursor Key
Move cursor to the left direction.
14. Right cursor Key
Move cursor to the right direction.
15. Input voltage/current On/Off Key
Enables and disables the load input voltage/current.
16. Mode Setting Key
Adjust the Mode setting (CC mode, CR mode, CV mode).
17. Range Setting Key
Set the range of CC mode and CR mode.
When you're in input on status, you can not use this key.
18. Slew Setting Key
Adjust the setting value of Slew mode(1~12 step).
19. IO/LOCAL Setting & Error Display Key
Adjust the Remote interface setting (RS232C, RS485, USB)
Press 3 seconds and there will be Error Number and message.
20. Short On/Off Setting Key
Adjust the maximum current that load can take.
21. Recall & Save Key
Click more than 3 seconds and enter to Recall Mode and open the saved data.
Click one time and enter to Save Mode and save the current mode, setting value.
22. ESC, Err Check, Protection off Key
This key has same function of ESC Key. When error occurs, use this key for checking.
23. B-Memory Setting and Factory mode Key
If you're in Dynamic Mode, This key function as B-Memory Setting Key.
Press 3 seconds and set the B-Memory status.
For the factory mode, Power on the load with pressing this key. you can enter to Factory mode.
There are a lot of menus you can use (User-Mem Clear, Auto Key Lock and etc.)