24. A-Memory Setting, Calibration mode
If you're in Dynamic Mode, This key function as A-Memory Setting Key.
Press for 3 seconds and set the A-Memory Setting
For the Calibration, Power on the load with pressing this key. You can enter to calibration mode.
In this mode, you can do calibration of current, voltage.
25. Dynamic Cycling time Setting, Dynamic Duty Setting
Press one time and set the velocity of Dynamic mode (0.0001 ~ 4s).
Press for 3 seconds and set the dynamic mode duty (0.3~97%)
26. Dynamic On/Off
Start and Stop the dynamic mode.
27. Cycling Sequence setting
Set the start step and finish step of cycling mode.
28. Cycling Repeat setting
Set the repeat time of step in cycling mode.
29. Cycling Step setting
Press one time and input Step information for cycling mode.
You can input Step Num, Mode Set, Value Setting, Slope Time Setting, Delay Time Setting.
Press for 3 seconds and input Fuse Time and Fuse Current for Fuse Mode.
30. Cycling On/ Off Key
Press one time and proceed cycling mode.
Press for 3 seconds and fuse mode is on.
- 9 -