CURR:RANG { H | L }
Command for setting CC Mode Range.
> H
CC Mode HIGH RANGE
> L
CC Mode LOW RANGE
ex1) CURR:RANG H
CC Mode HIGH RANGE Setting
ex2) CURR:RANG L
CC Mode LOW Range Setting
CURR:RANG?
Command for checking CC Mode RANGE status.
Return value
"H"
CC Mode HIGH RANGE
"L"
CC Mode LOW RANGE
CURR:SLEW {1|2|3|4|5|6|7|8|9|10|11|12}
Command for setting CC Mode's SLEW.
ex) CURR:SLEW 2
Set SLEW 2 in CC Mode.
CURR:SLEW{ H | L }?
Command for checking CC Mode's SLEW setting value.
Return value
"2"
SLEW setting value is 2 in CC Mode.
RES {value}
Command for setting input resistance value of CR Mode.
>value
Input resistance value.
ex) RES 10
Setting 10 OHM
RES?
Checking setting resistance value of CR Mode.
Return value
"res"
ex) RES?
Return value "10.000"
RES:RANG { H | M | L }
Command for setting CR Mode Range.
> H
CR Mode HIGH RANGE
> M
CR Mode MID RANGE
> L
CR Mode LOW RANGE
ex1) RES:RANG H
CR Mode HIGH RANGE Setting
ex1) RES:RANG H
CR Mode HIGH RANGE Setting
ex2) RES:RANG L
CR Mode LOW Range Setting
- 76 -