Document UT-MT-0778_EN
Page 24 of 39
Edition 11/03/2014
Supersedes edition 02/03/2014
LED INSET THRESHOLD/END LIGHT L
THE04
INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE
Ø320
Ø320
Ø100
1
50
1
50
Figure 12 – 12” shallow base for side or bottom ducts (method “B”)
1. Positioning jig
2. Align the jig notch with the mark on
the pavement
3. Circular level
4. Screws and spacers for the jig
mounting
5. Lobe knob for positioning jig levelling
6. 12” shallow base
7. Shallow base notches aligned with the
notch on the jig
Figure 13 – Shallow base installation details