Document UT-MT-0778_EN
Page 35 of 39
Edition 11/03/2014
Supersedes edition 02/03/2014
LED INSET THRESHOLD/END LIGHT L
THE04
INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE
1.
Dome
2.
O-Ring between dome
and lower cover
3.
O-Ring between dome
and lower cover
4.
O-Ring around the
dome
5.
Lower Cover
6.
12" Shallow base
7.
O-Ring between
fixture and 12"
Shallow base
Figure 23– Fixture Gaskets
Figure 24 – Prism Gasket
3.12.2
O-Ring replacement
Remove the old O-Ring from the groove and clean the flange mating surfaces and the
groove, scraping carefully. Take care not to damage the mating surface and the
bottom and sides of the groove. Position it in the centre of its groove and push it
inside.
NOTE 1:
Make sure that the proper O-Ring is re-inserted into the groove.
NOTE 2: The seat of an O-Ring gasket is dimensioned to allow the proper
positioning when compressed between the mating surfaces. Screws properly
tightened are important in obtaining a complete seal.
TIGHTENING TORQUE
lower cover HSCS M5x10
2.5 Nm
fixture locking screw
35 Nm (for shallow base)
25 Nm (for L-868 base, size B)