background image

21

BUD OPERATING MANUAL

© 2002 Design, 2011

Doc. No. 12-5259-r01 (7/21/11)

CAN BE USED AS

•  Dive Computer (Air or Nitrox) 

DIVE COMPUTER PERFORMANCE

•  Buhlmann ZHL-16c based Z+, or DSAT based, algorithm

•  No Deco limits closely follow PADI RDP

•  Decompression in agreement with Buhlmann ZHL-16c and French MN90

•  No Deco Deep Stops - Morroni, Bennett

•  Deco Deep Stops (not recommended) - Blatteau, Gerth, Gutvik

•  Altitude - Buhlmann, IANTD, RDP (Cross)

•  Altitude corrections and O2 limits based on NOAA tables 

OPERATIONAL PERFORMANCE

Function:

 

Accuracy:

•  Depth  

±1% of full scale

•  Timers 

1 second per day

Dive Counter:

•  Displays Dives #1 to 12

•  Resets to Dive #1, upon diving (after 24 hours with no dives)

Altitude:

•  Operational from sea level to 14,000 feet (4,270 meters) elevation

•  Measures ambient pressure every 30 minutes when inactive, upon activation, every 15 minutes while activated.

•  Does not measure ambient pressure when Wet.

•  Compensates for Altitudes above sea level beginning at 3,001 feet (916 meters) elevation and every 1,000 feet (305 meters) higher.

Power:

•  (1) 3 vdc, CR2430, Lithium battery (Panasonic or equivalent)

•  Shelf life 

Up to 5 years (dependent on battery manufacturer)

•  Replacement 

User (annual recommended)

•  Use Life 

100 dive hours if (1) 1 hour dives per dive day to 300 hours if (3) 1 hour dives per day

Battery  Icon:

 

•  Warning - icon on solid at 2.75 volts, Battery change recommended

•  Alarm - icon on flashing at 2.50 volts, change the Battery

Activation:

•   Manual - push button (recommended).

•   Automatic - when wet.

•   Cannot be manually activated deeper than 4 FT (1.2 M).

•   Cannot operate at elevations higher than 14,000 feet (4,270 meters)  

Operating Temperature:

•  Out of the water - between 20 °F and 140 °F (-6 and 60 °C).

•  In the water - between 28 °F and 95 °F (-2 and 35 °C). 

TLBG

 

  segments   

 

•  No Deco Normal zone 

  1 to 3        

 

•  No Deco Caution zone 

  4         

•  Decompression zone 

  5 (all)        

 

VARI

 

60 FT (18 M) & Shallower         Deeper than 60 FT (18 M)  

 

   

segments    FPM 

  MPM     segments      FPM    MPM

   

      0       0 - 10    0 - 3            0         0 - 20   0 - 6 

•  Normal zone 

      1       11 - 15    3.5 - 4.5        1         21 - 30  6.5 - 9

  Normal zone 

      2       16 - 20    5 - 6            2         31 - 40  9.5 - 12

  Normal zone 

      3       21 - 25    6.5 - 7.5        3         41 - 50  12.5 - 15

•  Caution zone 

      4       26 - 30    8 - 9            4         51 - 60  15.5 - 18

•  Too Fast zone (flashing)         5 (all)         > 30           > 9                   5 (all)              > 60       > 18 

NUMERIC DISPLAYS: 

Range: 

Resolution:

•  Dive Number 

0 to 12  

1

•  Surface Interval Time 

0:00 to 23:59 hr:min 

1 min

•  Time to Fly & Desat 

23:50 to 0:00 hr:min* 

1 min

   

(* starting 10 min after the dive)

•  FO2 Set Point 

Air, 21 to 50 % 

1 %

•  PO2 Value 

0.00 to 5.00 ATA 

.01 ATA

•  Depth 

0 to 330 FT (100 M) 

1 FT (.1/1 M )

•  Elapsed Dive Time 

0:00 to 9:59 hr:min 

1 min

•  Dive Time Remaining 

0:00 to 9:59 hr:min 

1 min

•  Safety Stop Time 

0:00 to 3:00 min:sec 

1 sec

•  Deco Stop Time 

0:00 to 9:59 hr:min 

1 min

•  Total Ascent Time 

0:00 to 9:59 hr:min 

1 min

•  Violation Countdown Timer 

23:50 to 0:00 hr:min 

1 min

MOD (Max Operating Depth): 

330 FT (100 M)

SPECIFICATIONS

Содержание BUD

Страница 1: ...1 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 BUD DIVE COMPUTER OPERATING MANUAL...

Страница 2: ...ORITHM 12 SAFETY STOP SS 12 DIVE TIME REMAINING DTR 12 NDC No Deco DTR 12 OTR O2 DTR 12 NO DECO MAIN AND ALTS 13 SAFETY STOP 13 DECOMPRESSION 13 CV CONDITIONAL VIOLATION 14 DV 1 DELAYED VIOLATION 1 14...

Страница 3: ...3 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 Welcome to OCEANIC and THANK YOU for choosing the BUD...

Страница 4: ...ating Manual Doc No 12 5258 2002 Design 2011 San Leandro CA USA 94577 TRADEMARK NOTICE Oceanic the Oceanic logo BUD and the BUD logo are all registered and unregistered trademarks of Oceanic All right...

Страница 5: ...5 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 FEATURES DISPLAYS...

Страница 6: ...equired Stop Depth is displayed on the Main Fig 5a Max Depth is displayed on Alternate Dive screens Fig 6a Times are shown in various formats Hour Minute Dive Time Remaining Fig 4b Elapsed Dive Time F...

Страница 7: ...7 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 ACTIVATION SETUP...

Страница 8: ...is low B 2 sec to access ALT 1 B 2 sec to access FLY SAT then step forward through other Surface selections Upon surfacing from dives the Dive Main will remain on display for the first 10 minutes wit...

Страница 9: ...oxygen calculations for Plan and DTR values The setting locks in for 24 hours after dives SET CONSERVATIVE FACTOR information includes Fig 17 Graphic SEt Graphic OFF or ON flashing with CF icon B 2 s...

Страница 10: ...tting and access SN SERIAL NUMBER Information displayed on this screen should be recorded and kept with your sales receipt it will be required in the event that your unit requires factory service Seri...

Страница 11: ...11 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 DIVE MODE...

Страница 12: ...to 20 FT 6 M for 1 second If you surface during the SS countdown the SS will be canceled for the remainder of that dive There is no Penalty if you surface prior to completing the SS or ignore it DTR...

Страница 13: ...ec to revert to Main SAFETY STOP MAIN information includes Fig 26 Stop Time min sec with STOP icon counting down Current Depth with FT or M icon Stop Depth with STOP and FT or M icons NX CF DSAT or Z...

Страница 14: ...s elapse Deco operation will continue with no off gassing credit given for time above the Stop Instead for each minute above the Stop 1 1 2 minutes of penalty time will be added to required Stop Time...

Страница 15: ...surface VARI while ascending B 2 sec to access ALT EDT Max Depth VGM on Surface Upon surfacing the graphic VIO will alternate with Surface Interval time until the unit shuts off after 24 hours The SU...

Страница 16: ...el the O2 value 100 will flash in place of DTR or Deco Stop Time and the graphic UP will flash Fig 43 until on the surface Upon surfacing the the O2 value 100 will alternate with Surface Interval time...

Страница 17: ...17 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 GENERAL...

Страница 18: ...lculations for repetitive dives are retained in the unit s memory while a new battery is installed BATTERY REPLACEMENT The Battery Compartment should only be opened in a dry and clean environment with...

Страница 19: ...ensure it is consistently clear and sharp in contrast throughout the screen Set the Date and Time Verify all Set Points prior to diving If any portions of the display are missing or appear dim or if...

Страница 20: ...0 03 54 0 05 0 04 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 57 0 05 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 DSAT ALGORITHM NDLS HR MIN AT ALTITUDE IMPERIAL Altitude 0 3001 4001...

Страница 21: ...r day Battery Icon Warning icon on solid at 2 75 volts Battery change recommended Alarm icon on flashing at 2 50 volts change the Battery Activation Manual push button recommended Automatic when wet C...

Страница 22: ...www OceanicWorldwide com E mail hello oceanicusa com OCEANIC NORTHERN EUROPE Augsburg Germany Tel 49 0 821 810342 0 Fax 49 0 821 810342 29 Web www oceanic de E mail office oceanic de OCEANIC ITALY Ge...

Страница 23: ...23 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 NOTES...

Страница 24: ...24 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 BUD DIVE COMPUTER OPERATING MANUAL...

Отзывы: