Oceanic BUD Скачать руководство пользователя страница 8

8

BUD OPERATING MANUAL

© 2002 Design, 2011

Doc. No. 12-5259-r01 (7/21/11)

ACTIVATION

To Activate the BUD, press and release B (the button). 

•  The unit will enter Diagnostic mode (Fig. 9), displaying all segments of the LCD as 8's, followed by dashes ( - - ), then a 

countdown from 9 to 0, checking the display and battery voltage to ensure that everything is within tolerance and functioning 

properly.  

•  After manual activation, it will also check the ambient barometric pressure, and calibrate its present depth as zero.  Begin-

ning at elevations of 3,001 feet (916 meters), it will recalibrate depth and adjust calculations every 2,000 feet (610 meters). 

The BUD will also automatically activate by water contact.  This is accomplished by bridging the gap between contacts located 

on the button and case.    

If no dive is made within 2 hours after initial activation, the unit will automatically deactivate.  If the wet contacts are still bridged, 

the unit will reactivate. 

WARNING:  If the unit is activated at elevations higher than 14,000 feet (4,267 meters), it will perform a diagnos-

tic check and immediately shutdown.

SURF MAIN, 

information includes (Fig. 10):

>  Surface Interval time (hr:min) with SURF icon; if no dive yet, this is time since activation.

>  Dive number with # icon, up to 12 for that operating period (0 if no dive made yet).

>  NX icon, if FO2 is set for Nitrox

>  DSAT (or Z+) icon, Algorithm selected.>  TLBG with icon, if any after a dive.

>  Battery icon, if voltage is low.

•  B (< 2 sec) to access ALT 1. 

•  B (2 sec) to access FLY/SAT, then step forward through other Surface selections.

Upon surfacing from dives, the Dive Main will remain on display for the first 10 minutes with Surface Interval in place of NDC 

and the SURF icon flashing (Fig. 11).  

After 10 minutes, the Surface Main will be displayed.

 

SURF ALT 1 (Last), 

information includes (Fig. 12):

>  Elapsed Dive Time (hr:min) of dive previously made while still activated with EDT icons.

>  LAST icon.

>  Max Depth with FT (or M) and MAX icons, of dive previously made while still activated (3 dashes if MOD exceeded). 

•  B (< 2 sec) to access ALT 2*.  

•  Reverts to Main in 5 seconds if B is not pressed.

SURF ALT 2*, 

information includes (Fig. 13):

>  Current %O2 saturation with SAT and O2% icons. 

>  PO2 Alarm setting (fixed at 1.40) with PO2 icon.

>  FO2 setting with FO2 and NX icons.

•  B (< 2 sec) to revert to Main. 

•  Reverts to Main in 5 seconds if B is not pressed.

*ALT 2 is not displayed if FO2 was set for AIR.

SURFACE SEQUENCE

 

Separate from the ALT screens, there is a sequence of selections in which you can -

>  view Time to Fly/Desaturate.

>  set FO2.

>  select Algorithm.

>  set Conservative Factor.

>  view Plan NDLs.

>  set Units.

>  view Serial Number.

Press B repeatedly (2 sec each time), to access and step through the sequence then return to the Surface Main.

While in the sequence, operation will revert to the Surface Main if B is not pressed within a period of 2 minutes.

The sequence cannot be accessed during the first 10 minutes on the surface following a dive. 

Fig. 9 - DIAGNOSTIC

Fig. 10 - SURFACE MAIN

(no dive yet)

Fig. 11 - DIVE MAIN

(< 10 min on surface)

Fig. 13 - SURFACE ALT 2

Fig. 12 - SURFACE ALT 1

(Last dive's data)

Содержание BUD

Страница 1: ...1 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 BUD DIVE COMPUTER OPERATING MANUAL...

Страница 2: ...ORITHM 12 SAFETY STOP SS 12 DIVE TIME REMAINING DTR 12 NDC No Deco DTR 12 OTR O2 DTR 12 NO DECO MAIN AND ALTS 13 SAFETY STOP 13 DECOMPRESSION 13 CV CONDITIONAL VIOLATION 14 DV 1 DELAYED VIOLATION 1 14...

Страница 3: ...3 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 Welcome to OCEANIC and THANK YOU for choosing the BUD...

Страница 4: ...ating Manual Doc No 12 5258 2002 Design 2011 San Leandro CA USA 94577 TRADEMARK NOTICE Oceanic the Oceanic logo BUD and the BUD logo are all registered and unregistered trademarks of Oceanic All right...

Страница 5: ...5 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 FEATURES DISPLAYS...

Страница 6: ...equired Stop Depth is displayed on the Main Fig 5a Max Depth is displayed on Alternate Dive screens Fig 6a Times are shown in various formats Hour Minute Dive Time Remaining Fig 4b Elapsed Dive Time F...

Страница 7: ...7 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 ACTIVATION SETUP...

Страница 8: ...is low B 2 sec to access ALT 1 B 2 sec to access FLY SAT then step forward through other Surface selections Upon surfacing from dives the Dive Main will remain on display for the first 10 minutes wit...

Страница 9: ...oxygen calculations for Plan and DTR values The setting locks in for 24 hours after dives SET CONSERVATIVE FACTOR information includes Fig 17 Graphic SEt Graphic OFF or ON flashing with CF icon B 2 s...

Страница 10: ...tting and access SN SERIAL NUMBER Information displayed on this screen should be recorded and kept with your sales receipt it will be required in the event that your unit requires factory service Seri...

Страница 11: ...11 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 DIVE MODE...

Страница 12: ...to 20 FT 6 M for 1 second If you surface during the SS countdown the SS will be canceled for the remainder of that dive There is no Penalty if you surface prior to completing the SS or ignore it DTR...

Страница 13: ...ec to revert to Main SAFETY STOP MAIN information includes Fig 26 Stop Time min sec with STOP icon counting down Current Depth with FT or M icon Stop Depth with STOP and FT or M icons NX CF DSAT or Z...

Страница 14: ...s elapse Deco operation will continue with no off gassing credit given for time above the Stop Instead for each minute above the Stop 1 1 2 minutes of penalty time will be added to required Stop Time...

Страница 15: ...surface VARI while ascending B 2 sec to access ALT EDT Max Depth VGM on Surface Upon surfacing the graphic VIO will alternate with Surface Interval time until the unit shuts off after 24 hours The SU...

Страница 16: ...el the O2 value 100 will flash in place of DTR or Deco Stop Time and the graphic UP will flash Fig 43 until on the surface Upon surfacing the the O2 value 100 will alternate with Surface Interval time...

Страница 17: ...17 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 GENERAL...

Страница 18: ...lculations for repetitive dives are retained in the unit s memory while a new battery is installed BATTERY REPLACEMENT The Battery Compartment should only be opened in a dry and clean environment with...

Страница 19: ...ensure it is consistently clear and sharp in contrast throughout the screen Set the Date and Time Verify all Set Points prior to diving If any portions of the display are missing or appear dim or if...

Страница 20: ...0 03 54 0 05 0 04 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 57 0 05 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 DSAT ALGORITHM NDLS HR MIN AT ALTITUDE IMPERIAL Altitude 0 3001 4001...

Страница 21: ...r day Battery Icon Warning icon on solid at 2 75 volts Battery change recommended Alarm icon on flashing at 2 50 volts change the Battery Activation Manual push button recommended Automatic when wet C...

Страница 22: ...www OceanicWorldwide com E mail hello oceanicusa com OCEANIC NORTHERN EUROPE Augsburg Germany Tel 49 0 821 810342 0 Fax 49 0 821 810342 29 Web www oceanic de E mail office oceanic de OCEANIC ITALY Ge...

Страница 23: ...23 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 NOTES...

Страница 24: ...24 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 BUD DIVE COMPUTER OPERATING MANUAL...

Отзывы: