DV 3 (DELAYED VIOLATION 3)

If you descend deeper than the MOD*, DTR and Current Depth will be displayed as with the Depth ones flashing (Fig. 35).

Max Depth on the ALT will also be displayed as 3 dashes.  

*MOD is the Max Operating Depth at which the BUD can properly perform calculations or provide accurate display information. Refer to the 

Specifications in the back.

Upon ascending above the MOD, Current Depth will be restored, however, Max Depth will continue to be displayed as dashes 

for the remainder of that dive.  

DTR will be restored if it is accurate, or remain as dashes if not.

VGM (VIOLATION GAUGE MODE)

During NORM dives, operation will enter VGM when Deco requires a Stop Depth greater than 70 FT (21 M).  

Operation would then continue in VGM during the remainder of that dive and for 24 hours after surfacing.  VGM turns the BUD 

into a digital instrument without any decompression or oxygen related calculations or displays. 

Upon activation of VGM, the full TLBG with the graphics VIO and UP flash for 10 seconds as a warning (Fig. 36). 

VGM Dive Main

, after 10 sec information includes (Fig. 37) -

>  Graphic VIO (in place of DTR) solid.

>  Current Depth with FT (or M) icon.

>  Graphic UP, flashing until on surface

>  VARI while ascending

•  B (< 2 sec) to access ALT (EDT & Max Depth).

VGM on Surface

Upon surfacing, the graphic VIO will alternate with Surface Interval time until the unit shuts off after 24 hours.  

The SURF icon will flash during the first 10 minutes (Fig. 38). 

Operation will also enter VGM 5 minutes after surfacing from a dive in which a Delayed Violation occurred. 

>  A full 24 hour continuous surface interval must then be served before all functions are restored.

HIGH PO2

Warning >> at 1.20 (ATA).

Alarm >> at 1.40 (ATA), except in Deco then at 1.60 only.

During No Deco -

When PO2 (partial pressure of oxygen) increases to the Warning level; the PO2 value will alternate with Current Depth for 10 

seconds with the graphic UP displayed (Fig. 39).  

After 10 seconds, Current Depth is restored.  The graphic UP remains on solid until PO2 decreases below 1.20.

If PO2 continues to increase and reaches the Alarm level (1.40), the PO2 value will again alternate with Current Depth and the 

graphic UP will flash (Fig. 40) until PO2 is < 1.40.

During Deco -

If PO2 reaches 1.60 while in Deco, the PO2 value (=> 1.60) with icon will alternate with Current Depth (Fig. 41). 

When PO2 decreases below 1.60, Current Depth will restored.

No indication is given to ascend (graphic UP), you control action to be taken according to your expertise and training. 

Fig. 35 -  DV3 MAIN

Fig. 36 -  VGM ACTIVATION

Fig. 37 -  VGM DIVE MAIN

alt w/

Fig. 38 -  VGM SURFACE

Fig. 39  - PO2 WARNING

Fig. 40 - PO2 ALARM

Fig. 41 - PO2 ALARM DECO

alternate

Содержание BUD

Страница 1: ...1 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 BUD DIVE COMPUTER OPERATING MANUAL...

Страница 2: ...ORITHM 12 SAFETY STOP SS 12 DIVE TIME REMAINING DTR 12 NDC No Deco DTR 12 OTR O2 DTR 12 NO DECO MAIN AND ALTS 13 SAFETY STOP 13 DECOMPRESSION 13 CV CONDITIONAL VIOLATION 14 DV 1 DELAYED VIOLATION 1 14...

Страница 3: ...3 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 Welcome to OCEANIC and THANK YOU for choosing the BUD...

Страница 4: ...ating Manual Doc No 12 5258 2002 Design 2011 San Leandro CA USA 94577 TRADEMARK NOTICE Oceanic the Oceanic logo BUD and the BUD logo are all registered and unregistered trademarks of Oceanic All right...

Страница 5: ...5 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 FEATURES DISPLAYS...

Страница 6: ...equired Stop Depth is displayed on the Main Fig 5a Max Depth is displayed on Alternate Dive screens Fig 6a Times are shown in various formats Hour Minute Dive Time Remaining Fig 4b Elapsed Dive Time F...

Страница 7: ...7 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 ACTIVATION SETUP...

Страница 8: ...is low B 2 sec to access ALT 1 B 2 sec to access FLY SAT then step forward through other Surface selections Upon surfacing from dives the Dive Main will remain on display for the first 10 minutes wit...

Страница 9: ...oxygen calculations for Plan and DTR values The setting locks in for 24 hours after dives SET CONSERVATIVE FACTOR information includes Fig 17 Graphic SEt Graphic OFF or ON flashing with CF icon B 2 s...

Страница 10: ...tting and access SN SERIAL NUMBER Information displayed on this screen should be recorded and kept with your sales receipt it will be required in the event that your unit requires factory service Seri...

Страница 11: ...11 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 DIVE MODE...

Страница 12: ...to 20 FT 6 M for 1 second If you surface during the SS countdown the SS will be canceled for the remainder of that dive There is no Penalty if you surface prior to completing the SS or ignore it DTR...

Страница 13: ...ec to revert to Main SAFETY STOP MAIN information includes Fig 26 Stop Time min sec with STOP icon counting down Current Depth with FT or M icon Stop Depth with STOP and FT or M icons NX CF DSAT or Z...

Страница 14: ...s elapse Deco operation will continue with no off gassing credit given for time above the Stop Instead for each minute above the Stop 1 1 2 minutes of penalty time will be added to required Stop Time...

Страница 15: ...surface VARI while ascending B 2 sec to access ALT EDT Max Depth VGM on Surface Upon surfacing the graphic VIO will alternate with Surface Interval time until the unit shuts off after 24 hours The SU...

Страница 16: ...el the O2 value 100 will flash in place of DTR or Deco Stop Time and the graphic UP will flash Fig 43 until on the surface Upon surfacing the the O2 value 100 will alternate with Surface Interval time...

Страница 17: ...17 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 GENERAL...

Страница 18: ...lculations for repetitive dives are retained in the unit s memory while a new battery is installed BATTERY REPLACEMENT The Battery Compartment should only be opened in a dry and clean environment with...

Страница 19: ...ensure it is consistently clear and sharp in contrast throughout the screen Set the Date and Time Verify all Set Points prior to diving If any portions of the display are missing or appear dim or if...

Страница 20: ...0 03 54 0 05 0 04 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 57 0 05 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 DSAT ALGORITHM NDLS HR MIN AT ALTITUDE IMPERIAL Altitude 0 3001 4001...

Страница 21: ...r day Battery Icon Warning icon on solid at 2 75 volts Battery change recommended Alarm icon on flashing at 2 50 volts change the Battery Activation Manual push button recommended Automatic when wet C...

Страница 22: ...www OceanicWorldwide com E mail hello oceanicusa com OCEANIC NORTHERN EUROPE Augsburg Germany Tel 49 0 821 810342 0 Fax 49 0 821 810342 29 Web www oceanic de E mail office oceanic de OCEANIC ITALY Ge...

Страница 23: ...23 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 NOTES...

Страница 24: ...24 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 BUD DIVE COMPUTER OPERATING MANUAL...

Отзывы: