Oceanic BUD Скачать руководство пользователя страница 13

13

BUD OPERATING MANUAL

© 2002 Design, 2011

Doc. No. 12-5259-r01 (7/21/11)

NO DECO MAIN,

 information includes (Fig. 22) -

>  DTR (hr:min) with NDC (or O2) icon.

>  Current Depth with FT (or M) icon.

>  Max Depth with MAX and FT (or M) icons

>  EDT (Elapsed Dive Time) with DIVE and min icons

>  NX, CF, DSAT (or Z+), icons - those that apply.

>  TLBG.

>  VARI, while ascending.

•  B (< 2 sec) to access ALTs.

Upon ascending to 2 FT (0.6 M) during a dive, Surface Interval time will be displayed with the SURF icon flashing for the first 10 

minutes with Current Depth displayed as 0 (Fig. 23).

•  B (< 2 sec) to access Dive ALTs.

If a descent is made to 5 FT (1.5 M) for 5 seconds during that first 10 minutes, the dive will be continued.  Surface time will not be added to 

Elapsed Dive Time.

After 10 minutes elapse on the surface, operation will revert to the Surface Main with full access given to the other surface items.

NO DECO ALT 1,

 information includes (Fig. 24) -

>  EDT (hr:min) with EDT icon.

>  Max Depth with FT (or M) and MAX icons.

•  B (< 2 sec) to access ALT 2 if NX, or revert to Main if Air.

•  Revert to Main in 5 sec, if B not pressed.

NO DECO ALT 2 

(if Nitrox), information includes (Fig. 25) -

>  O2 saturation (accumulation) with O2% icon.

>  Current PO2 value (ATA) with PO2 icon.

>  FO2 Set Point with FO2 and NX icons.

•  5 sec or B (< 2 sec) to revert to Main.

SAFETY STOP MAIN,

 information includes (Fig. 26) -

>  Stop Time (min:sec) with STOP icon, counting down.

>  Current Depth with FT (or M) icon.

>  Stop Depth with STOP and FT (or M) icons.

>  NX, CF, DSAT (or Z+), icons - those that apply.

>  TLBG.

•  B (< 2 sec) to access ALTs**.

** The SS features up to 3 ALT displays which are similar to the No Deco Main, ALT1, and ALT2 displays, respectively.

DECOMPRESSION

Decompression mode activates when theoretical No Decompression time and depth limits are exceeded.  

Upon entry into Deco, the full TLBG will flash (Fig. 27) for 10 seconds.  The Stop Depth digits will flash while 10 FT (3 M) below 

the required Stop Depth. 

>  Once within 10 FT (3 M) below the required Stop Depth (stop zone), the Stop Depth digits will stop flashing.

To fulfill your decompression obligation, you should make a safe controlled Ascent to a depth slightly deeper than, or equal to, 

the required Stop Depth indicated and decompress for the Stop Time indicated.

The amount of decompression credit time that you receive is dependent on Depth, with slightly less credit given the deeper you 

are below the Stop Depth indicated.  

You should stay slightly deeper than the required Stop Depth indicated until the next shallower Stop Depth appears.  Then, you 

can slowly ascend to, but not shallower than that indicated Stop Depth. 

Fig. 22  - NO DECO MAIN

Fig. 23  - NO DECO MAIN

(on surface < 10 min)

Fig. 24  - NO DECO ALT 1

Fig. 25  - NO DECO ALT 2

Fig. 26  - SS MAIN

Fig. 27 - DECO ENTRY

Содержание BUD

Страница 1: ...1 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 BUD DIVE COMPUTER OPERATING MANUAL...

Страница 2: ...ORITHM 12 SAFETY STOP SS 12 DIVE TIME REMAINING DTR 12 NDC No Deco DTR 12 OTR O2 DTR 12 NO DECO MAIN AND ALTS 13 SAFETY STOP 13 DECOMPRESSION 13 CV CONDITIONAL VIOLATION 14 DV 1 DELAYED VIOLATION 1 14...

Страница 3: ...3 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 Welcome to OCEANIC and THANK YOU for choosing the BUD...

Страница 4: ...ating Manual Doc No 12 5258 2002 Design 2011 San Leandro CA USA 94577 TRADEMARK NOTICE Oceanic the Oceanic logo BUD and the BUD logo are all registered and unregistered trademarks of Oceanic All right...

Страница 5: ...5 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 FEATURES DISPLAYS...

Страница 6: ...equired Stop Depth is displayed on the Main Fig 5a Max Depth is displayed on Alternate Dive screens Fig 6a Times are shown in various formats Hour Minute Dive Time Remaining Fig 4b Elapsed Dive Time F...

Страница 7: ...7 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 ACTIVATION SETUP...

Страница 8: ...is low B 2 sec to access ALT 1 B 2 sec to access FLY SAT then step forward through other Surface selections Upon surfacing from dives the Dive Main will remain on display for the first 10 minutes wit...

Страница 9: ...oxygen calculations for Plan and DTR values The setting locks in for 24 hours after dives SET CONSERVATIVE FACTOR information includes Fig 17 Graphic SEt Graphic OFF or ON flashing with CF icon B 2 s...

Страница 10: ...tting and access SN SERIAL NUMBER Information displayed on this screen should be recorded and kept with your sales receipt it will be required in the event that your unit requires factory service Seri...

Страница 11: ...11 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 DIVE MODE...

Страница 12: ...to 20 FT 6 M for 1 second If you surface during the SS countdown the SS will be canceled for the remainder of that dive There is no Penalty if you surface prior to completing the SS or ignore it DTR...

Страница 13: ...ec to revert to Main SAFETY STOP MAIN information includes Fig 26 Stop Time min sec with STOP icon counting down Current Depth with FT or M icon Stop Depth with STOP and FT or M icons NX CF DSAT or Z...

Страница 14: ...s elapse Deco operation will continue with no off gassing credit given for time above the Stop Instead for each minute above the Stop 1 1 2 minutes of penalty time will be added to required Stop Time...

Страница 15: ...surface VARI while ascending B 2 sec to access ALT EDT Max Depth VGM on Surface Upon surfacing the graphic VIO will alternate with Surface Interval time until the unit shuts off after 24 hours The SU...

Страница 16: ...el the O2 value 100 will flash in place of DTR or Deco Stop Time and the graphic UP will flash Fig 43 until on the surface Upon surfacing the the O2 value 100 will alternate with Surface Interval time...

Страница 17: ...17 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 GENERAL...

Страница 18: ...lculations for repetitive dives are retained in the unit s memory while a new battery is installed BATTERY REPLACEMENT The Battery Compartment should only be opened in a dry and clean environment with...

Страница 19: ...ensure it is consistently clear and sharp in contrast throughout the screen Set the Date and Time Verify all Set Points prior to diving If any portions of the display are missing or appear dim or if...

Страница 20: ...0 03 54 0 05 0 04 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 57 0 05 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 DSAT ALGORITHM NDLS HR MIN AT ALTITUDE IMPERIAL Altitude 0 3001 4001...

Страница 21: ...r day Battery Icon Warning icon on solid at 2 75 volts Battery change recommended Alarm icon on flashing at 2 50 volts change the Battery Activation Manual push button recommended Automatic when wet C...

Страница 22: ...www OceanicWorldwide com E mail hello oceanicusa com OCEANIC NORTHERN EUROPE Augsburg Germany Tel 49 0 821 810342 0 Fax 49 0 821 810342 29 Web www oceanic de E mail office oceanic de OCEANIC ITALY Ge...

Страница 23: ...23 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 NOTES...

Страница 24: ...24 BUD OPERATING MANUAL 2002 Design 2011 Doc No 12 5259 r01 7 21 11 BUD DIVE COMPUTER OPERATING MANUAL...

Отзывы: