64
SET WET ACTIVATION information includes (Fig. 57):
> Graphic WET
> Set Point graphic ON (or OFF) flashing.
Pressing and releasing the S button will toggle between ON
and OFF.
Pressing and releasing the A button momentarily (< 2
seconds) will save the setting and/or advance to the SET
UNITS screen with the Set Point flashing.
Pressing and releasing the A button momentarily and
repeatedly (< 2 seconds each time) will step through the
other SET U screens.
Depressing the A and S buttons simultaneously for 2
seconds will save the setting and revert back to the SET U
screen.
Depressing and holding the M button for 2 seconds or if no
button is pressed for a period of 2 minutes operation will
revert to the NORM or GAUG SURF MAIN screen.
HINT: To change this setting while operating in
FREE Mode, first access the NORM SURF Mode.
Fig. 57 - SET WET
ACTIVATION
Prior to the first dive
of a repetitive
series, WET Activa-
tion must be set ON
for the ATOM to
enter Dive Mode
while operating as a
Watch.