background image

To prevent injury to the user or other people and property damage, the following instructions 
must be followed. Incorrect operation may cause harm or damage. The seriousness is 
classified by the warning symbols below.

Safety Precautions

This symbol indicates the possibility of death or serious injury.

Definition of symbols used in this manual are as shown below.

!

!

WARNING

Always do this.

Never do this.

!

CAUTION

This symbol indicates the possibility of injury or damage to property.

Plug in power plug 

properly.

Do not modify power cord

length or share the outlet

with other appliances. 

Always ensure effective

grounding.

Unplug the unit if strange

sounds, smell, or smoke

is detected.

Keep firearms away.

Ventilate room before operating air

conditioner if there is a gas leakage from

another appliance.

   Otherwise, Thit may causec

   electric shock or fire due to

   excess heat generation.

  This may cause electric shock or 

  fire due to heat generation.

  Incorrect grounding may cause 

  electric shock.

  This may cause fire and electric

  shock.

  This may cause fire.

  This may cause explosion, fire and, burns.

  This may cause electric shock or

 fire  due to heat generation.

  This may cause electric shock.

  This may cause failure of machine

  or electric shock.

  This may cause fire and electric 

  shock.

  This may cause fire and electric 

  shock.

Do not operate or stop the

unit by inserting or pulling 

out the power plug.

Do not operate with wet

hands or in damp 

environment.

Do not allow water to run

into electric parts.

Do not use the socket if it is

loose or damaged.

Do not use the power cord

close to heating appliances.

!

!

!

!

!

WARNING

!

2

!

 

Do not damage or use an 

 

unspecified power cord.

  This may cause electric shock or 

  fire.

  If the power cord is damaged, it 

  must be replaced by the manufac-

  turer or an authorised service

  center or a similarly qualified per- 

  son in order to avoid a hazard.

 

 

Do not point airflow at 

 

room occupants directly.

  This could be harmful to your 

  health.

 

!

 

Always install circuit

 

 

breaker and a dedicated

 

 

power circuit.

  Incorrect installation may cause 

  fire and electric shock.

 

 

Do not open the unit

 

 

during operation.

  This may cause electric shock.

 

 

Do not use the power cord near

 

 

flammable gas or combustibles, such

 

 

as gasoline, benzene, thinner, etc.

   This may cause an explosion or 

   fire.

 

 

Do not disassemble or modify unit.

  This may cause failure and electric shock.

!

   Otherwise, This may causec

   Otherwise, this may cause

  This may cause explosion, fire, and burns.

Содержание OBZ-06CR

Страница 1: ...Before using this product please read the instructions carefully and keep for future reference MODEL OBZ 06CR OBZ 08CR www oceanbreezecomfort com...

Страница 2: ...e that they do not play with the appliance If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The applian...

Страница 3: ...ck or fire due to heat generation This may cause electric shock This may cause failure of machine or electric shock This may cause fire and electric shock This may cause fire and electric shock Do not...

Страница 4: ...unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified service technician 3 appliance or accident Appearance...

Страница 5: ...ct Manufacturer Do not under any circumstances cut remove or bypass the grounding prong Power cord with 3 prong grounding plug and current detection device Operation of Current Detection Device Applic...

Страница 6: ...ES ACTIVATES TIMER CHECK FILTER RESET BUTTON SETS MODE ENERGY SAVER MODE SLEEP MODE CLEAN AIR MODE only on some models SET FAN SPEED TURNS UNIT ON OR OFF UNIT CONTROL Temp Temp Timer Timer On Off Slee...

Страница 7: ...PERATING MODE Press the MODE button Auto Cool Dry Fan Low Auto Med High Clean Air Fan Mode Follow Me Energy Saver On Off DO THIS To select mode press the Mode button Each time you press the button the...

Страница 8: ...Dry Fan Low Auto Med High Clean Air SLEEP FEATURE Press SLEEP button DO THIS In this mode the selected temperature will increase by one degree 30 minutes after the mode is selected The temperature wil...

Страница 9: ...MER OFF Press or hold the UP or DOWN button to change the then at 1 1 hour increments up to 24 hours T he control w ill will count down the time remaining until start The selected time will register i...

Страница 10: ...mostat allowing for the precise temperature control at its location ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure here are more features in your control that you...

Страница 11: ...m sharp metal edges and aluminum fins on front and rear coils Top Rail Hardware 3 8 Screws 4 Top Rail 1 on the unit For 10000Btu h models only Tool Needed Phillips Screwdriver A Remove the air conditi...

Страница 12: ...filter panels are on the proper side When installed the flange for securing the panel in place to the window sill should be facing into the room necessary for proper condensed water utilization and dr...

Страница 13: ...ing screws through the frame lock and into the sill Fig 8 NOTE To prevent window sill from splitting drill 1 8 3mm pilot holes before driving screws 2 13mm 4 Fig 7 Fig 8 12 C Once the panel has been i...

Страница 14: ...MIN 38 mm Sash Board thickness as required for proper pitch to rear along entire sill Fasten with nails or screws Fig 13 Removing AC From Window 13 Remove sash seal from between windows and unscrew sa...

Страница 15: ...e replacing Or instead of washing you may vacuum the filter clean Note Never use hot water over 40 C 104 F to clean the air filter Never attempt to operate the unit without the air filter Cabinet Clea...

Страница 16: ...ent may be touching the cold coil located behind the air filter Straighten the tube away from the coil The temperature may need to be set lower for the air conditioner to activate The compressor may h...

Страница 17: ...d the unit initially Water dripping INDOORS when the unit is on COOL The air conditioner may have been improperly installed Tilt the air conditioner slightly outward to allow water to drain out Refer...

Страница 18: ...Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Switching Sound Droplets of water hitting condenser during normal operation may...