background image

16

Problem

Solution

Air conditioner turns 

on and off rapidly

Noises coming from 

the unit when cooling

- A dirty air filter may be obstructing the cool air. Clean the filter as 

  instructed on the ‘CARE AND CLEANING SECTION’ of this manual.

- In cases where the outside temperature may be extremely high, set 

  the FAN speed to a higher setting to circulate the air cool air better.
- This may be the operating sound of air movement and is normal. 

  However, if the noise seems too loud, set the FAN to a lower speed 

  setting.

- The noise may be due to window vibration. This can happen when 

  the air conditioner is installed incorrectly. Refer to the installation 

  instruction on page 10 or check with the person who installed the 

  unit initially.

Water dripping 

INDOORS when the 

unit is on COOL

- The air conditioner may have been improperly installed. Tilt the air 

conditioner slightly outward to allow water to drain out. Refer to 

installation instructions on page 10 or check with the person who 

installed the unit initially.

Water dripping 

OUTSIDE when 

unit is cooling

- The unit may be accumulating a large quantity of moisture as it is 

  dehumidifying a humid room. This is normal operation for excessively 

  humid weather.

- Remote control may not be within range of the unit. Be sure to have 

  the remote control within a 20 foot radius in front of the unit.

- The remote control signal may be obstructed. Remove any obstructions 

  interfering with signal.

Room is too cold

- The temperature setting may be too low. Increase the temperature to 

  a more comfortable level.

Remote control 

'FOLLOW ME' mode 

deactivates prematurely 
(on some models only)

Содержание OBZ-06CR

Страница 1: ...Before using this product please read the instructions carefully and keep for future reference MODEL OBZ 06CR OBZ 08CR www oceanbreezecomfort com...

Страница 2: ...e that they do not play with the appliance If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The applian...

Страница 3: ...ck or fire due to heat generation This may cause electric shock This may cause failure of machine or electric shock This may cause fire and electric shock This may cause fire and electric shock Do not...

Страница 4: ...unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified service technician 3 appliance or accident Appearance...

Страница 5: ...ct Manufacturer Do not under any circumstances cut remove or bypass the grounding prong Power cord with 3 prong grounding plug and current detection device Operation of Current Detection Device Applic...

Страница 6: ...ES ACTIVATES TIMER CHECK FILTER RESET BUTTON SETS MODE ENERGY SAVER MODE SLEEP MODE CLEAN AIR MODE only on some models SET FAN SPEED TURNS UNIT ON OR OFF UNIT CONTROL Temp Temp Timer Timer On Off Slee...

Страница 7: ...PERATING MODE Press the MODE button Auto Cool Dry Fan Low Auto Med High Clean Air Fan Mode Follow Me Energy Saver On Off DO THIS To select mode press the Mode button Each time you press the button the...

Страница 8: ...Dry Fan Low Auto Med High Clean Air SLEEP FEATURE Press SLEEP button DO THIS In this mode the selected temperature will increase by one degree 30 minutes after the mode is selected The temperature wil...

Страница 9: ...MER OFF Press or hold the UP or DOWN button to change the then at 1 1 hour increments up to 24 hours T he control w ill will count down the time remaining until start The selected time will register i...

Страница 10: ...mostat allowing for the precise temperature control at its location ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure here are more features in your control that you...

Страница 11: ...m sharp metal edges and aluminum fins on front and rear coils Top Rail Hardware 3 8 Screws 4 Top Rail 1 on the unit For 10000Btu h models only Tool Needed Phillips Screwdriver A Remove the air conditi...

Страница 12: ...filter panels are on the proper side When installed the flange for securing the panel in place to the window sill should be facing into the room necessary for proper condensed water utilization and dr...

Страница 13: ...ing screws through the frame lock and into the sill Fig 8 NOTE To prevent window sill from splitting drill 1 8 3mm pilot holes before driving screws 2 13mm 4 Fig 7 Fig 8 12 C Once the panel has been i...

Страница 14: ...MIN 38 mm Sash Board thickness as required for proper pitch to rear along entire sill Fasten with nails or screws Fig 13 Removing AC From Window 13 Remove sash seal from between windows and unscrew sa...

Страница 15: ...e replacing Or instead of washing you may vacuum the filter clean Note Never use hot water over 40 C 104 F to clean the air filter Never attempt to operate the unit without the air filter Cabinet Clea...

Страница 16: ...ent may be touching the cold coil located behind the air filter Straighten the tube away from the coil The temperature may need to be set lower for the air conditioner to activate The compressor may h...

Страница 17: ...d the unit initially Water dripping INDOORS when the unit is on COOL The air conditioner may have been improperly installed Tilt the air conditioner slightly outward to allow water to drain out Refer...

Страница 18: ...Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Switching Sound Droplets of water hitting condenser during normal operation may...

Страница 19: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Отзывы: