Before calling for service, review this list. It may save you time and expense. This list includes common 

problems that may not be the result of defective workman-ship or materials in this appliance.

 

TROUBLESHOOTING TIPS

15

Problem

Solution

Air conditioner 

does not start

Air From unit does

not feel cool enough

Air conditioner is 

cooling, but room is 

still warm and ice 

seems to be forming 

on the cooling coils 

behind the AC casing

- Power cord may have been disconnected from the outlet. Push 

   plug in firmly into the outlet.

- Fuse or circuit breaker may have been tripped. In this case, replace 

  fuse with a time delay type or reset circuit breaker.

- Power button may be on OFF. Press the power button to turn ON.

- Current detection device (on some models only) on the power cord 

  may have been tripped. Press the RESET button on the current 

  detection device plug.

- If the room temperature is below 62°F (17°C), cooling may not begin 

  until the temperature is higher.

- Temperature sensor element may be touching the cold coil, located 

  behind the air filter. Straighten the tube away from the coil.

- The temperature may need to be set lower for the air conditioner to 

  activate.

- The compressor may have been shut off by abrupt mode changes. 

  Wait approximately 3 minutes and listen for compressor to restart 

  when set in COOL mode.

- The outdoor temperature of below 62°F (17°C) may be affecting operation. 

  To defrost the coil, set the unit to FAN ONLY

- The air filter may be dirty. Clean the filter as instructed on the ‘CARE 

  AND CLEANING SECTION’ of this manual.

- The temperature may be set too high. Set the temperature control to 

  a lowering setting.

- Air directional louvers may be positioned improperly. Position louvers 

  for better air distribution.

- The front of the unit may be obstructed by curtains, blinds, or other 

  foreign bodies, restricting the air distribution. Clear the area around 

  the front of AC unit.

- Cold air may be escaping the room through open doors, windows or 

  openings. Close all open doors, windows, and other openings.

- In a warm room, a just activated air conditioner may need time to 

  remove the heat present in the room and distribute cool air.

Troubleshooting section

Содержание OBZ-06CR

Страница 1: ...Before using this product please read the instructions carefully and keep for future reference MODEL OBZ 06CR OBZ 08CR www oceanbreezecomfort com...

Страница 2: ...e that they do not play with the appliance If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The applian...

Страница 3: ...ck or fire due to heat generation This may cause electric shock This may cause failure of machine or electric shock This may cause fire and electric shock This may cause fire and electric shock Do not...

Страница 4: ...unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified service technician 3 appliance or accident Appearance...

Страница 5: ...ct Manufacturer Do not under any circumstances cut remove or bypass the grounding prong Power cord with 3 prong grounding plug and current detection device Operation of Current Detection Device Applic...

Страница 6: ...ES ACTIVATES TIMER CHECK FILTER RESET BUTTON SETS MODE ENERGY SAVER MODE SLEEP MODE CLEAN AIR MODE only on some models SET FAN SPEED TURNS UNIT ON OR OFF UNIT CONTROL Temp Temp Timer Timer On Off Slee...

Страница 7: ...PERATING MODE Press the MODE button Auto Cool Dry Fan Low Auto Med High Clean Air Fan Mode Follow Me Energy Saver On Off DO THIS To select mode press the Mode button Each time you press the button the...

Страница 8: ...Dry Fan Low Auto Med High Clean Air SLEEP FEATURE Press SLEEP button DO THIS In this mode the selected temperature will increase by one degree 30 minutes after the mode is selected The temperature wil...

Страница 9: ...MER OFF Press or hold the UP or DOWN button to change the then at 1 1 hour increments up to 24 hours T he control w ill will count down the time remaining until start The selected time will register i...

Страница 10: ...mostat allowing for the precise temperature control at its location ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure here are more features in your control that you...

Страница 11: ...m sharp metal edges and aluminum fins on front and rear coils Top Rail Hardware 3 8 Screws 4 Top Rail 1 on the unit For 10000Btu h models only Tool Needed Phillips Screwdriver A Remove the air conditi...

Страница 12: ...filter panels are on the proper side When installed the flange for securing the panel in place to the window sill should be facing into the room necessary for proper condensed water utilization and dr...

Страница 13: ...ing screws through the frame lock and into the sill Fig 8 NOTE To prevent window sill from splitting drill 1 8 3mm pilot holes before driving screws 2 13mm 4 Fig 7 Fig 8 12 C Once the panel has been i...

Страница 14: ...MIN 38 mm Sash Board thickness as required for proper pitch to rear along entire sill Fasten with nails or screws Fig 13 Removing AC From Window 13 Remove sash seal from between windows and unscrew sa...

Страница 15: ...e replacing Or instead of washing you may vacuum the filter clean Note Never use hot water over 40 C 104 F to clean the air filter Never attempt to operate the unit without the air filter Cabinet Clea...

Страница 16: ...ent may be touching the cold coil located behind the air filter Straighten the tube away from the coil The temperature may need to be set lower for the air conditioner to activate The compressor may h...

Страница 17: ...d the unit initially Water dripping INDOORS when the unit is on COOL The air conditioner may have been improperly installed Tilt the air conditioner slightly outward to allow water to drain out Refer...

Страница 18: ...Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Switching Sound Droplets of water hitting condenser during normal operation may...

Страница 19: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Отзывы: