![Oce 3165 Скачать руководство пользователя страница 85](http://html2.mh-extra.com/html/oce/3165/3165_operators-manual_3210180085.webp)
Safety information
85
Safety data sheet Océ 3165 Digital Copier
©1997 Océ-Technologies B.V.
The content of this safety data sheet is subject o the disclaimer of liability on
page 84 of this manual.
Océ (UK) Ltd
Langston Road
telephone 0181.508.5544
Loughton, Essex IG10 3SL
fax 0181.508.6689
Number:
E-683-a-UK
United Kingdom
Date:
August 1997
Model
Océ 3165
Description
Electrostatic copying machine, console model, plain paper
, organic photoconductive belt,
powder toner , automatic duplexing
Max. process speed
62 A4 copies/min or 30 A3 copies/min.
Dimensions
Width
1622
mm
Depth
885
mm
Height
1280
mm
Weight
413
kg
Voltage
220-240
V
Frequency
50
Hz
Current-rated
8,9-8,5
A
Current-max
13
A
Power consumption, operation
2000
W
Power consumption, standby
600
W
Mains connection
Cable with plug
Safety class
I
(IEC 536) Protective earth connection
Protection class
IP 20
(IEC 529)
Sound pressure level
(at operator/bystander
position)
Standby:
In operation:
35 dB(A)
mainbody 60 dB(A);
incl. optionals 63 dB(A);
impulse
∆
L
i
= 3 dB(A)
Sound power level
49 dB(A)
mainbody 73 dB(A);
incl. optionals 75 dB(A)
Radio interference
Complies with Directive 89/336/EEC
Radiation
Below the Threshold Limit V
alue for UV radiation (TL
V list of ACGIH)
Heat emission
Standby 600 W (controller 32 W); in operation 2000 W (controller 40 W)
Ozone emission
0,01 mg/min at continuous operation
Room volume
Recommendation: min. 30 m
3
Room ventilation
Recommendation: min. 15 m
3
/h (natural ventilation)
For heat evacuation extra ventilation may be necessary
Use simulation at random
operation
Room volume and ventilation as recommended
Daily copy volume (much more than average
)
7500
A4
Total worktime
8
h
Ozone concentrations:
- Time weighted average
0,001
mg/m
3
(0.0005
ppm)
- Peak
0,003
mg/m
3
(0.0015
ppm)
Threshold Limit V alue/Occupational Exposure Limit
(T ime W eighted A verage) for ozone
0,2
mg/m
3
(0,1
ppm)
Odour Perception Limit for ozone
0,04
mg/m
3
(0,02
ppm)
Consumables
Océ Master (Océ Material Safety Data Sheet E-193)
Océ F3 T oner (Océ Material Safety Data Sheet E-182)
Océ Copying Materials
This apparatus is suitable for processing recycling paper which complies with the
requirements of ENV 12281
Additional safety information
The ozone filter does not have to be replaced for keeping the ozone concentration in the
workplace below 0,04 mg/m
3
(the life of the filter equals that of the apparatus)
CE-Compliance
Approved according to
Approved according to
Low V oltage Directive
EMC Directive
73/23/EEC
89/336/EEC
Содержание 3165
Страница 1: ...Key Operator Manual Oc 3165...
Страница 6: ...6 Oc 3165 Key Operator Manual...
Страница 42: ...42 Oc 3165 Key Operator Manual...
Страница 70: ...70 Oc 3165 Key Operator Manual...
Страница 81: ...81 Oc 3165 Key Operator Manual Appendix A Safety information...
Страница 95: ...95 Oc 3165 Key Operator Manual Appendix B Miscellaneous...