practicable. For guidance on the best location refer to the WMO CIMO Guide 

2

. The location must be 

accessible for yearly maintenance. 
 

4.3  Site preparation 

The OMC-160 anemometer bracket can be mounted on a vertical pipe end with an external diameter 
between 35-60 mm. The pipe end should stop within 30 mm above the mounting clamp. In the vertical 
plane there will be about 75 mm free space between the end of the pipe and the cup unit. 
 
Make sure that the mast is properly fixed to withstand rugged wind forces. For calculation purposes: the 
wind-capturing surface of the OMC-160 anemometer is approx. 700 cm

2

 (0.07 m

). The pipe end must 

be free of vibration. 
 
The following tools are required for mechanical installation of the OMC-160 anemometer: 

 

wrench 10 mm for M6 capped nuts 

 

wrench 16 mm for M10 nuts on U-bolts 

 

compass and/or binocular telescope 

 
 

4.4  Mounting / mechanical installation 

First connect the mounting clamp to the mast / pipe end. The top of the mounting clamp must be 
mounted less than 30 mm under the end of the pipe to prevent the pipe end blocking the wind flow to the 
cup unit. 
 

Securely tighten the nuts on the U-bolts, preventing the nuts vibrate loose. 

 

4.5  Assembly of cup and vane 

The wind-sensors are shipped with the wind vane and cups disconnected from their appropriate units. On 
the common unit, the upper spindle is for the wind direction sensor, and the lower spindle for the wind 
speed sensor. To prevent damaging the wind vane and cups, properly mount the sensor/bracket 
combination on the mast before fitting the wind vane and cup-unit whenever possible. 
 
The shafts of the OMC-160 anemometer and the inside of the cup unit and vane unit are conical. This 
enables fastening of the capped nut without the shaft turning along. 
 
The cup unit and the vane blade are made of light materials for optimum response to the wind. Both are 
balanced to provide accurate measurement and to prevent vibration. Take care not to damage the cup 
unit or the vane blade while mounting. 
 
Place the vane unit and mounting materials on the upper shaft in the following sequence: 

1)  Vane unit  
2)  Plain washer 
3)  Capped nut 

 
Place the cup unit and mounting materials on the lower shaft in the following sequence: 

1)  Cup unit 
2)  Spring washer 
3)  Capped nut 

 

                                                      

2

 Guide to Meteorological Instruments and Methods of Observation, WMO No. 8, 6th Edition, World Meteorological  

 
Organisation, Geneva, Switzerland, ISBN 978-92-63-10008-5 

Содержание OMC-160-3

Страница 1: ...OMC 160 3 OMC 160 3 Anemometer Manual Version 3 2 November 2017 Author Observator Instruments...

Страница 2: ...OMC 160 3 Manual Page 2 Revisions 2 04 November 2013 previous versions OMC 160 2 3 0 May 2017 OMC 160 3 introduction 3 1 August 2017 OMC 160 3 reviewed manual 3 2 November 2017 Update specifictions...

Страница 3: ...issioning 13 5 1 Commissioning procedure 13 5 1 1 Alignment of the wind vane 13 6 Maintenance 15 6 1 Maintenance schedule preventive maintenance 15 6 2 Removing the OMC 160 anemometer from its locatio...

Страница 4: ...OMC 160 3 Manual Page 4 Page intentionally left blank...

Страница 5: ...rine and offshore environment and it has proven to be robust and reliable over the years The OMC 160 3 continues the robust build quality improved with the latest technology which will make it even mo...

Страница 6: ...moving parts which can rotate fast during strong winds Keep clear of the cup and vane during strong winds The Observator OMC 160 Anemometer is usually installed at height Technicians maintaining the s...

Страница 7: ...sensor is a rotary cup type unit manufactured in stainless steel and polycarbonate The three cups are cone shaped for optimum response to varying winds The vane unit is made in stainless steel 3 4 Th...

Страница 8: ...g arm cup unit vane unit U bolts mounting materials this manual on CD Note that additional materials that were simultaneously ordered for the same order might be packed in the OMC 160 box 4 2 Location...

Страница 9: ...Securely tighten the nuts on the U bolts preventing the nuts vibrate loose 4 5 Assembly of cup and vane The wind sensors are shipped with the wind vane and cups disconnected from their appropriate un...

Страница 10: ...OMC 160 3 Manual Page 10...

Страница 11: ...Recommended cable shielded 2x2x0 75mm2 like OMC 494 Terminal 5 must be used for NMEA shield connection Terminal 8 is meant as 0 reference in case the receiver has a RS422 input a separate wire should...

Страница 12: ...B On Direction within 1 5 degrees N Direction is 0 degrees Direction within 355 359 degrees 4 6 3 Status LED s Table 3 Lower LED s on juntionbox PCB On Off S Speed sensor OK Speed sensor fault D Direc...

Страница 13: ...ing release the button Check alignment when correct the middle LED N should lit Repeat procedure if a correction is required Close the junction box and tighten carefully Note that the accuracy of the...

Страница 14: ...pray Large branches move wires whistle umbrellas are difficult to control 7 28 33 13 9 17 1 Near gale Mounting sea 4 m with foam blown in streaks downwind Whole trees in motion inconvenience in walkin...

Страница 15: ...the power supply tot the sensor display data collection unit or PSU 2 Remove the vane unit and the cup unit The cup unit and the vane blade are made of light materials for optimum response to the win...

Страница 16: ...tions First remove the cup unit or vane unit from their body by unscrewing the capped nut and lifting the unit Unscrew the bearing housing 2 or 3 6 5 Replacement of ball bearings and sensor PCB s Firs...

Страница 17: ...cified 1 First remove PCB see Sensor PCB 6 removal 2 Remove the 3 columns 4 3 Loosen the sensor element hex screw 8 4 Remove the sensor element 5 5 Remove the bearing cover plate 3 Speed head only if...

Страница 18: ...renewed care should be taken not to apply excessive force on the new bearings When re installing the complete bearing housing with the sensor PCB s care should be taken that the internal wiring is pro...

Страница 19: ...atus A Data Valid V Data invalid WIVER 1 1 WI OBS c c c c c c c c c c x hh CR LF 1 2 3 4 5 6 7 8 9 10 1 Total number of sentences needed 1 to 9 1 2 Sentence number 1 to 9 1 3 Device type WI 4 Vendor I...

Страница 20: ...nd speed 0 75 m s Accuracy wind speed Better than 2 Threshold speed Approx 0 3 m s Distance constant 1 68 meters Measuring range wind direction 0 360 no gap Direction accuracy non linearity etc 2 degr...

Страница 21: ...tacting Type and model of equipment Serial number Original order number and year of purchase If it is impossible to find out where the instrument was purchased please contact the manufacturer Observat...

Страница 22: ...in a dry place Note that this is required as the system is only weatherproof when mounted in an upright position 10 3 Reshipping the instrument Whenever the OMC 160 3 anemometer is shipped e g for cal...

Страница 23: ...n support software Connect to the NMEA output of the sensor terminal 3 4 and setup the terminal 4800 8 n 1 Power cycle the sensor and press ESC within 5s The main menu should appear OMC 160 3 Main Men...

Страница 24: ...OMC 160 3 Manual Page 24 12 Dimensional Drawing...

Страница 25: ...OMC 160 3 Manual Page 25 13 EU Declaration of Conformity...

Отзывы: