11 Advanced configuration
Function
Default
Option
Baud rate
: 4800
9600
Output Interval
: 4 Hz
1 Hz
NMEA Identifier
: WI
2 Characters (A..Z) free selectable
NMEA VER Sentence : Enabled
off
Speed Linearization
: Enabled
off
Changing these settings requires a RS485 (half duplex = 2 wire) connection (RS485 to USB converter),
PC and a terminal program. Any basic terminal program will do, you can download a free terminal
program
‘OMC-Terminal’ from our website:
https://observator.com/en/support/software
Connect to the NMEA output of the sensor (terminal 3 & 4) and setup the terminal (4800*,8,n,1).
Power cycle the sensor and press [ESC] within 5s.
The main menu should appear:
=================================
= OMC-160-3 Main Menu =
=================================
= Version 00.90 B006 =
=================================
1 Serial
: 160399999
2 Baudrate
: 4800
3 Output Interval
: 4 Hz
4 NMEA Identifier
: WI
5 NMEA VER Sentence
: Enabled
6 Speed Linearization
: Enabled
7 North Offset
: 215
0 Exit Menu
1 - 7 Change Setting
Settings can be changed with the corresponding numbers.
We advise to keep speed linearization enabled unless you compensate the sensor otherwise.
North Offset will be overwritten during the alignment procedure (with the pushbutton).
*if output was set to 9600, use 9600 here as well.
Содержание OMC-160-3
Страница 1: ...OMC 160 3 OMC 160 3 Anemometer Manual Version 3 2 November 2017 Author Observator Instruments...
Страница 4: ...OMC 160 3 Manual Page 4 Page intentionally left blank...
Страница 10: ...OMC 160 3 Manual Page 10...
Страница 24: ...OMC 160 3 Manual Page 24 12 Dimensional Drawing...
Страница 25: ...OMC 160 3 Manual Page 25 13 EU Declaration of Conformity...