B_1RREC / POU_1RREC Series
Installation & Service Instructions
030099-499 RevOrig
pg 13 of 22
© Copyright 2014 OASIS Europe
11.
When fitted to a cooler the height from the floor to the top of the bottle should not exceed 1.5
metres.
12.
Ensure that the appliance is positioned to give access to the plug after the unit is installed.
13.
Recommended ambient temperatures for correct operation of the unit are between 10ºC and 32ºC
14.
For safe operation, the unit should always be placed on a level surface.
15.
Check the available power supply against the water cooler data plate to ensure correct electrical
service. (DO NOT PLUG IN AT THIS TIME )
16.
Cold water temperatures may be adjusted via a slotted screw on the body of the control (can be
accessed through a hole in the finger plate on the back of the unit). Turning this screw in the
clockwise direction will make the water colder (and vice versa)
17.
The A-weighted sound pressure level of this appliance is below 70 dB
CAUTION: DO NOT INSTALL THE WATER COOLER IN AN AREA WHERE
WATER JETS MAY BE USED
Installing CO2 bottle
1.
Install the CO2 bottle into the filter compartment. (Refer to “Accessing Filter Compartment”
section)
2.
Connect the CO2 bottle to the CO2 pressure regulator.
3.
Tighten the regulator with the correct spanner.
4.
Secure bottle with the Velcro strap.
5.
Turn valve on the CO2 bottle to the open position and check for CO2 leaks.
6.
Set the gauge on the pressure regulator to 4 bar (60PSI)
Cook, Cold, & Carbo Model
1.
Invert a water bottle on top of the cooler, check all connections for leaks.
2.
Connect unit to power supply; for models with an IEC power inlet:
a.
Connect the female portion of the approved power cord into the IEC inlet
b.
Insert the plug top of the power cord into the electrical supply socket
3.
Draw water from the Cook and Cold faucets
4.
Press & hold purge button, and draw water from carbo faucet
5.
Set to OPEN the CO2 regulator
6.
Set Flow Regulator to Max open (Turn allen key anti-clockwise fully)
7.
Draw water from the carbo faucet, and slowly rotate the allen key (Clockwise) until desired
carbonation level is obtained.
8.
Allow about 30 minutes for the water to chill after the cooler is plugged in. (Optimum cold
water temperatures will not be reached for several hours).
Hot, Cold, & Carbo Model
1.
Invert a water bottle on top of the cooler, check all connections for leaks.
2.
Connect unit to power supply; for models with an IEC power inlet:
a.
Connect the female portion of the approved power cord into the IEC inlet
b.
Insert the plug top of the power cord into the electrical supply socket
3.
Open the hot faucet until water flows freely
4.
Draw water from the hot and cold faucets
5.
Place the hot tank heater switch in the “ON” position
6.
Press & hold purge button, and draw water from carbo faucet
7.
Set to OPEN the CO2 regulator