background image

B_1RREC / POU_1RREC Series 

Installation & Service Instructions 

 

 
 

 

 

030099-499 RevOrig 

pg 7 of 22  

         © Copyright 2014 OASIS Europe 

General Information 

 

The B_1RREC & POU_1RREC Series coolers are designed for use with a supply of potable 
water. The cooler should not be used with water supplies of unknown bacterial quality or those 
that are not already fit for human consumption. The machine should only be used with a potable 
drinking water supply. 

 

This unit is suitable for indoor use in domestic, commercial & industrial locations. They should 
not be sited in locations where they may be subjected to rain or snow. 

 

Cooling System 

 

This cooler is designed with a removable reservoir. The reservoir can be replaced with a 
sanitised unit during routine maintenance services. 

 

The cold water temperature is preset at the factory at approximately 4°C (39°F) – the water 
temperature is controlled by a thermostat that is located on the back of the unit. Cold water 
temperatures may be adjusted via a slotted screw on the body of the control (can be accessed 
through the hole in the metal finger plate on the back of the unit.). Turning this screw in the 
clockwise direction will make the water colder (and vice versa). 

 

Hot Water System                                     

 

 

The hot water temperature is preset at the factory at approximately 88°C (190°F) – the water 
temperature is controlled by a thermostat that is located on the hot tank.  Hot water temperatures 
may be adjusted depending on the hot tank model.

 

 

Carbonated Water Circuit 

 

The carbonation level of the water is based on coldness of the water and pressure of the CO2 
bottle, & the setting of the flow regulator. The carbonation level in the water can be increased by 
either raising the CO2 pressure (which is adjustable in some models) or reducing the 
temperature of the CO2 water, or adjusting the flow regulator (which is accessible through the 
right side panel) 

 

Purging of the CO2 circuit is necessary at initial start up & after sanitization of the reservoir. 
The purge button is located on the left side panel 

 

Ambient Water Circuit 

 

The water in the ambient water circuit is not cooled - the temperature of the water will be the 
same as the temperature of the water that comes out of the BOTTLE / building water supply and 

Содержание POU_1RREC Series

Страница 1: ...INSTALLATION SERVICE INSTRUCTIONS B_1RREC B_1RREC POU_1EC POU_1RREC Series Coolers...

Страница 2: ...Y AVAILABLE FROM THE MANUFACTURER OR ITS SERVICE AGENT THIS APPLIANCE MUST BE EARTHED Contents Technical Specification Pre Delivery Inspection Filter Installation Installing the OASIS green filter sys...

Страница 3: ...B_1RREC POU_1RREC Series Installation Service Instructions 030099 499 RevOrig pg 3 of 22 Copyright 2014 OASIS Europe Wiring Diagram Models BXRRHSY POUX1RRHSY BX1RRKY POUX1RRKY...

Страница 4: ...B_1RREC POU_1RREC Series Installation Service Instructions 030099 499 RevOrig pg 4 of 22 Copyright 2014 OASIS Europe Models BE1RRECHSY EUR PC BE1RRECKY EUR PC POUE1RRECHSY EUR PC POUE1RRECKY EUR PC...

Страница 5: ...B_1RREC POU_1RREC Series Installation Service Instructions 030099 499 RevOrig pg 5 of 22 Copyright 2014 OASIS Europe Modele BX1RRECHSY EUR PC BX1RRECKY EUR PC POUX1RRECHSY EUR PC POUX1RRECKY EUR...

Страница 6: ...B_1RREC POU_1RREC Series Installation Service Instructions 030099 499 RevOrig pg 6 of 22 Copyright 2014 OASIS Europe Modele BE1RRHSY EUR PC BE1RRKY EUR PC POUE1RRHSY EUR PC POUE1RRKY EUR PC...

Страница 7: ...e control can be accessed through the hole in the metal finger plate on the back of the unit Turning this screw in the clockwise direction will make the water colder and vice versa Hot Water System Th...

Страница 8: ...r supply cord and then clean the condenser with a small stiff non wire brush Following this procedure will ensure adequate air circulation through the condenser for efficient and economical operation...

Страница 9: ...table depending on model CO2 regulators may differ depending on region Spare Parts Oasis International supplies spare parts for all of its watercoolers For European service please check the OASIS web...

Страница 10: ...e cooler to or from your premises you should ensure that a shipping bag is placed over the cooler This will prevent damage to the cabinet caused by coolers rubbing against one another in the back of t...

Страница 11: ...n to the inlet side of the filter system and the upper portion to the outlet side of the filter system Installing the OASIS green filter system POU Only Both the OASIS EZ clip and EZ turn filters can...

Страница 12: ...ould be added BOTTLE VERSION TO PUT BOTTLE WATER COOLER INTO SERVICE 1 This unit is suitable for indoor use in domestic commercial industrial locations They should not be sited in locations where they...

Страница 13: ...e Velcro strap 5 Turn valve on the CO2 bottle to the open position and check for CO2 leaks 6 Set the gauge on the pressure regulator to 4 bar 60PSI Cook Cold Carbo Model 1 Invert a water bottle on top...

Страница 14: ...ucet until the water is cool 3 Remove the bottle from the reservoir 4 Drain water in the reservoir through Hot Cold and then Carbo faucets 5 Disconnect cooler from power supply 6 Set to CLOSE the CO2...

Страница 15: ...an independent isolating valve This is intended so that the cooler can be replaced without draining long lengths of piping EUROPE ONLY In accordance with EPDWA guidelines the installation must also i...

Страница 16: ...ut a general inspection of the cooler ensuring that o There are no marks or physical damage to the cooler o That all accessories are present o That all the wires and electrical connections are in plac...

Страница 17: ...the approved power cord into the IEC inlet b Insert the plug top of the power cord into the electrical supply socket 3 Draw water from the Cook and Cold faucets 4 Press hold purge button and draw wate...

Страница 18: ...Turn the drain valve counter clockwise to open 9 Turn the drain valve to the closed position when the tank is empty ALWAYS DRAIN ALL WATER WHEN FREEZING TEMPERATURES ARE ANTICIPATED AND BEFORE SHIPPI...

Страница 19: ...servoir with the probe Place one hand inside the reservoir on the sleeve and push downward on the reservoir until it is resting on the insulation 2 Reattach the upper faucet FTG s to the reservoir by...

Страница 20: ...the unit and allow the ice inside the cooler to melt Water dispensed from the cold system is not chilled o Ensure that the cooler is not located in direct sunlight o Check that the thermostat on the r...

Страница 21: ...he refrigeration system you may need to remove the side panel s from the cabinet Please follow the instructions given below to carry out this operation SAFETY INSTRUCTIONS Isolate the water cooler fro...

Страница 22: ...pecific Cooler Instruction HTML Link Carbonation Circuit Please refer to Specific Cooler Instruction HTML Link Hot Tank Please refer to Specific Component Instruction HTML Link THIS APPLIANCE MUST BE...

Отзывы: