30
- EN -
9 Fault
finding
9.1
Fault Finding Chart
Fault Cause
Remedy
No water jet emerges
The Jumping Jet Rainbow Flash is too deep
in the water
Adapt unit to the water depth
Power plug of pump or 12V control box not
inserted
Connect unit to the power supply
The jet diaphragm not centred around the
water jet
Adjust the jet diaphragm such that the water
jet can pass unhindered
No basic program active
Activate a basic program using the
controller
Water emerges from the nozzle
uncontrolled
The water does not pass the centre of the
jet diaphragm
Adjust the jet diaphragm such that the water
jet can pass unhindered
Jet length shortens
Filter and screen are clogged
Clean filter and screen
The Jumping Jet Rainbow Flash is too deep
in the water
Adapt unit to the water depth
The water jet contours seem
diffused, jet loses its crystal clear
appearance
Water jet is torn apart by strong wind
—
Filter and screen are clogged
Clean filter and screen
Pump takes in air
Check the pump immersion depth
Lighting has failed
The LED of the spotlight is defective
Contact the OASE service
9.2
OASE-Service - Contact
If you need the OASE-Service please contact the
OASE-Service Department Tel.-Nr .0049 5454-80-143 Fax.-Nr. 0049 5454-80-235.
The address is:
OASE GmbH
Serviceabteilung
Tecklenburger Straße 161
D-48477 Hörstel-Riesenbeck
Germany