EN
‐
14
FiltoSmart
100/200/300
Connecting
the
hose
The
procedure
is
identical
for
the
inlet
(IN)
and
outlet
(OUT).
How
to
proceed:
K
1. Shorten
the
hose
to
the
required
length.
–
Chose
the
length
so
that
the
hose
cannot
kink
in
the
intended
installation
position.
2. Screw
the
union
nut
onto
the
hose
connector
of
the
connection
unit.
3. Push
the
hose
onto
the
hose
connector
and
turn
the
union
nut
counter
‐
clockwise
to
fix
the
hose
in
place.
4. Push
the
other
end
of
the
hose
onto
the
hose
con
‐
nector
at
the
suction
unit/flow
‐
out
unit
and
turn
the
union
nut
counter
‐
clockwise
to
fix
the
hose
in
place.
C
Fasten
the
suction
unit
and
flow
‐
out
unit
in
the
aquarium
using
suction
cups.
COMMISSIONING/START
‐
UP
N O T E
Thoroughly
rinse
out
all
filter
material
with
warm
tap
water
before
using
for
the
first
time
in
order
to
remove
any
soiling.
(
→
Cleaning/replacing
the
filter
media)
N O T E
Ensure
that
the
pump
never
runs
dry!
The
pump
will
be
destroyed.
Regularly
check
the
water
level
and
circulation
in
the
filter
and
in
the
aquarium.
How
to
proceed:
N
•
Completely
fill
the
container
with
water
and
place
it
next
to
the
aquarium.
–
Fill
the
container
via
the
opening.
For
this,
remove
the
blind
plug.
–
When
starting
it
up
for
the
first
time,
ensure
that
the
connection
unit
is
max.
80
cm
below
the
sur
‐
face
of
the
water.
Ensure
that
the
water
outlet
(flow
‐
out
pipe
or
water
distributor)
is
not
sub
‐
merged.
–
A
completely
filled
filter
may
be
more
than
80
cm
below
the
surface
of
the
water.
Note
the
maxi
‐
mum
head
height.
(
→
Technical
data)
•
Route
each
power
connection
cable
such
that
it
forms
a
drip
loop.
Switching
on:
Connect
the
unit
to
the
mains.
The
unit
switches
on
immediately.
When
the
unit
is
switched
on,
it
takes
several
minutes
for
the
air
to
escape
from
the
unit
(this
makes
a
noise).
Adjust
the
flow
at
the
flow
regulator
if
necessary.
(
→
Assembling
the
suction
unit)
Switching
off:
Disconnect
the
unit
from
the
mains.
TROUBLESHOOTING
Malfunction
Cause
Remedy
Unit
does
not
start
up.
No
mains
voltage
Check
the
mains
voltage.
Impeller
unit
blocked
Clean
Excessive
height
difference
between
the
top
edge
of
the
aquarium
and
the
suction
unit
Reduce
the
height
difference
Water
level
in
the
unit
too
low
Top
up
water
Water
flow
insufficient
Filter
housing
or
impeller
unit
soiled
Clean
Impeller
unit
worn
Replace
the
impeller
unit.
Flow
incorrectly
set
Correct
the
setting
Foam
filter
soiled
Clean
Activated
carbon
soiled
Clean
Ceramic
substrate
soiled
Clean
Suction
basket
clogged
Clean
suction
basket.
Pipework
soiled
Clean
suction
unit,
flow
‐
out
unit
and
hoses.
Insufficient
filtering
performance Foam
filter
soiled
Clean
Foam
filter
worn
Replace
Ceramic
substrate
soiled
Clean
Ceramic
substrate
worn
Replace
Activated
carbon
exhausted
Replace
Increased
noise
Air
in
the
filter,
vent
hose
on
the
pump
not
correctly
positioned.
Correct
the
position
of
the
vent
hose.
Содержание FiltoSmart 100
Страница 1: ...FiltoSmart 100 200 300 44407_Gebrauchsanleitung_FiltoSmartFiltoSmartThermo indd 1 08 01 16 14 10...
Страница 3: ...3 C FST0004...
Страница 4: ...4 FiltoSmart 100 200 300 D 1 2 E 1 2 FST0008 FST0012 F 2 1 1 FST0009...
Страница 5: ...5 G 3 1 4 4 2 1 FST0010 H FST0006...
Страница 6: ...6 FiltoSmart 100 200 300 I FSt0015...
Страница 7: ...7 J FiltoSmart 300 FiltoSmart 100 200 FST0016...
Страница 8: ...8 FiltoSmart 100 200 300 K 2 3 4 OUT IN 2 3 4 1 FST0017...
Страница 10: ...10 FiltoSmart 100 200 300 O 100 200 300 1 2 FST0018...
Страница 31: ......
Страница 32: ...55175 11 17 OASE North America INC www oase livingwater com...