manualshive.com logo in svg
background image

-  EN  - 

14 

 

 

Error messages 

 

Once a malfunction has been remedied, the error message automatically disappears. 

Error message 

Cause 

Remedy 

WARNING 
NO WATER

 

The pump has run dry (dry run protection has tripped). 

  Flood the pump. 

  Fully submerge the pump for operation in a pond. 

  Vent the supply line. 

  Remove any blockage from the supply line. 

Filter housing clogged (dry run protection has tripped). 

Clean the pump. 

WARNING 
MOTOR BLOCKED 

Impeller unit is blocked (dry run protection has tripped). 

Disconnect the power supply and remove obstacle. Then 

switch the pump on again. 

WARNING 
HIGH TEMPERATURE 

Ambient temperature for dry installation is too high. 

  Avoid exposure to direct sunlight. 

  Note maximum water temperature of +35°C. 

Water temperature too high 

Note maximum water temperature of +35°C. 

WARNING 
HIGH POWER 

Current consumption too high 

  Impeller unit running sluggishly 

  Excessively soiled water 

Clean the pump. 

 

 

 

 

 

Storage/overwintering 

 

The unit is frost-proof to -20

°C. If lower temperatures are expected, the unit must be removed and put into storage. 

How to correctly store the unit: 

 

  Protect the EGC plug from moisture and dirt. 

 

 

 

Wear parts 

 

The following components are wear parts and are excluded from the warranty: 

 

  EGC plug seal 

 

 

 

Disposal 

 

 

N O T E

 

Do not dispose of this unit with domestic waste. 

  Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system provided for 

this purpose. 

 

 

 

Spare parts 

 

The use of original parts from OASE ensures continued 

safe and reliable operation of the unit. 

Please visit our website for spare parts drawings and spare 

parts. 

 

 

 

www.oase-livingwater.com/spareparts

 

 

 

Downloaded from http://www.watergardeningdirect.com

Содержание Eco Control

Страница 1: ...48626 09 16 Eco Control 48626 GA_Eco Control_A5_end_ 21 09 16 11 21 Seite 2 Downloaded from http www watergardeningdirect com...

Страница 2: ...2 A AMX0029 B C AMX0031 AMX0032 D AMX0030 E AMX0035 Downloaded from http www watergardeningdirect com...

Страница 3: ...ale Wassertemperatur von 35 C einhalten WARNING HIGH POWER Stromaufnahme zu hoch Laufeinheit schwerg ngig Starke Wasserverschmutzung Pumpe reinigen Lagern berwintern Das Ger t ist frostsicher bis 20 C...

Страница 4: ...o judge and carry out the work commissioned to him her This also includes the recognition of possible hazards and the adherence to the pertinent regional and national standards rules and regula tions...

Страница 5: ...ng frame for fastening the device to the wall or for fitting it to the ground stake or holding clip 3 Ground stake 4 Holding clip for fastening the device to the pump handle Product Description Eco Co...

Страница 6: ...t the plug to the left hand EGC socket N O T E The device will be destroyed if water penetrates the EGC sockets Close the EGC sockets with EGC plugs or a protection cap Operation Control system overvi...

Страница 7: ...he speed is shown as a percentage SFC is deactivated SFC MODE SFC is activated it is not possible to adjust the speed SFC mode MIN MID MAX Adjustment only for SPEED Change the speed using the arrow ke...

Страница 8: ...US 28000 DFC MODE SCENE 1 DFC MODE OFF DFC MODE SCENE 1 Only display DFC Seasonal Flow Control ON Activated OFF Deactivated DFC MODE SCENE 1 SCENE 12 DFC deactivated No display Select the next display...

Страница 9: ...Note maximum water temperature of 35 C WARNING HIGH POWER Current consumption too high Impeller unit running sluggishly Excessively soiled water Clean the pump Storage overwintering The unit is frost...

Страница 10: ...dning Dimensioner V gt NO Tekniske data Tilkobling grensesnitt Lengde stikkledninger M l Vekt SV Tekniska data Anslutning gr nssnitt L ngd anslutningsledning M tt Vikt FI Tekniset tiedot Liit nt Liit...

Страница 11: ...e kast i alminnelig husholdningsavfall NB Les bruksanvisningen SV Dammskyddad Skyddad mot droppvatten Skydda mot direkt solstr l ning F r inte kastas i hush llsso porna Varning L s igenom bruksanvisni...

Страница 12: ...48626 10 16 Downloaded from http www watergardeningdirect com...

Отзывы: