- EN -
11
Fastening the device to the wall
How to proceed:
D
1. Remove the retaining frame and fasten it to the wall using suitable screws.
2. Fit the device into the retaining frame.
– Ensure that the device is properly engaged in the retaining frame.
Connect the unit
How to proceed:
E
1. Remove the protection cap from the unit.
2. Fit the plug connector and secure with the two screws (max. 2.0 Nm).
– Ensure that the rubber seal is clean and fits exactly.
– Replace the rubber seal if damaged.
– Only connect the plug to the left-hand EGC socket.
N O T E
The device will be destroyed if water penetrates the EGC sockets.
•
Close the EGC sockets with EGC plugs or a protection cap.
Operation
Control system overview
AMX0033
Description
Function
1 Two-line display with backlighting
2 LED ON/OFF
Indicates whether the pump is switched on or off.
3 ON/OFF button
For switching the pump on or off.
4 Arrow keys
For changing values in the menus or selecting other lines in the
menu.
5 Mode button
For selecting the next menu in the display.
The selection is continuous. It continues from the last menu to the first
menu.
6 LED MODE
Indicates the pump status.