Menu: Aquarius Eco Expert pump 

 

When the Aquarius Eco Expert pump is connected, the following menus and setting possibilities are available. 

 

 

 

 

 

 

 

Description 

 

 

AQUARIUS    28000 
PUMP               OFF

 

 

  Connected pump (e.g. Aquarius 28000) 

  The pump is switched off. 

 

Setting 

  Switch on the pump via the ON/OFF button. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AQUARIUS    28000 
PUMP             100 %

 

 

  Connected pump (e.g. Aquarius 28000) 

  The pump is switched on. 

 

Operating modes 

 

SPEED

: The speed is shown as a percentage (DFC is deactivated). 

 

DFC MODE

: DFC is activated (it is not possible to adjust the speed). 

–  DFC mode (SCENE 1 … SCENE 12) 

 

Adjustment (only for 

SPEED

  Change the speed using the arrow keys. 

0 %

: Min. speed, 

100 %

: Max. speed 

 

 

 

 

 

AQUARIUS    28000 
DFC MODE   SCENE 1

 

 

 

 

 

 

 

 

 

 

 

 

DFC MODE       OFF 
DFC MODE   SCENE 1

 

 

Only display 

 

DFC

 (Seasonal Flow Control) 

– 

ON

: Activated 

– 

OFF

: Deactivated 

 

DFC-MODE

 (SCENE 1 … SCENE 12) 

–  DFC deactivated: No display 

  Select the next display using the arrow keys. 

 

 

 

 

 

 

 

 

 

 

 

POWER         250 W 
RPM         2300/MIN

 

 

Only display 

  Current power consumption of the pump in watts 

– 

Display precision: ±5 % of the max. pump capacity

 

  Current speed of the pump in rpm 

  Select next/previous display using the arrow keys. 

 

 

 

 

 

 

 

 

 

 

 

RUNTIME        45 H 
SN        1234567890

 

 

Only display 

  Total pump operating time in hours 

  Pump serial number 

 

 

 

 

 

 

 

 

 

 

 

SET DFC    SCENE 1 

DFC MODE  –

›  

 OFF 

 

  DFC is switched off. 

 

Setting 

  Switch on DFC 

 

 

 

 

 

 

 

 

 

 

SET DFC –› SCENE 1 
DFC MODE        ON

 

 

  DFC is switched on, program 1 is selected 

 

Setting 

  Program selection (SCENE 1 … SCENE 12) and switching DFC off using the 

arrow keys  

 

 

 

 

 

 

 

 

 

 

SET DFC –› SCENE 12 
DFC MODE        ON 

 

 

 

 

 

Downloaded from http://www.watergardeningdirect.com

Содержание Eco Control

Страница 1: ...48626 09 16 Eco Control 48626 GA_Eco Control_A5_end_ 21 09 16 11 21 Seite 2 Downloaded from http www watergardeningdirect com...

Страница 2: ...2 A AMX0029 B C AMX0031 AMX0032 D AMX0030 E AMX0035 Downloaded from http www watergardeningdirect com...

Страница 3: ...ale Wassertemperatur von 35 C einhalten WARNING HIGH POWER Stromaufnahme zu hoch Laufeinheit schwerg ngig Starke Wasserverschmutzung Pumpe reinigen Lagern berwintern Das Ger t ist frostsicher bis 20 C...

Страница 4: ...o judge and carry out the work commissioned to him her This also includes the recognition of possible hazards and the adherence to the pertinent regional and national standards rules and regula tions...

Страница 5: ...ng frame for fastening the device to the wall or for fitting it to the ground stake or holding clip 3 Ground stake 4 Holding clip for fastening the device to the pump handle Product Description Eco Co...

Страница 6: ...t the plug to the left hand EGC socket N O T E The device will be destroyed if water penetrates the EGC sockets Close the EGC sockets with EGC plugs or a protection cap Operation Control system overvi...

Страница 7: ...he speed is shown as a percentage SFC is deactivated SFC MODE SFC is activated it is not possible to adjust the speed SFC mode MIN MID MAX Adjustment only for SPEED Change the speed using the arrow ke...

Страница 8: ...US 28000 DFC MODE SCENE 1 DFC MODE OFF DFC MODE SCENE 1 Only display DFC Seasonal Flow Control ON Activated OFF Deactivated DFC MODE SCENE 1 SCENE 12 DFC deactivated No display Select the next display...

Страница 9: ...Note maximum water temperature of 35 C WARNING HIGH POWER Current consumption too high Impeller unit running sluggishly Excessively soiled water Clean the pump Storage overwintering The unit is frost...

Страница 10: ...dning Dimensioner V gt NO Tekniske data Tilkobling grensesnitt Lengde stikkledninger M l Vekt SV Tekniska data Anslutning gr nssnitt L ngd anslutningsledning M tt Vikt FI Tekniset tiedot Liit nt Liit...

Страница 11: ...e kast i alminnelig husholdningsavfall NB Les bruksanvisningen SV Dammskyddad Skyddad mot droppvatten Skydda mot direkt solstr l ning F r inte kastas i hush llsso porna Varning L s igenom bruksanvisni...

Страница 12: ...48626 10 16 Downloaded from http www watergardeningdirect com...

Отзывы: