Remove Both Barrier covers using the keys provided
And place the Covers somewhere safe to prevent them
getting damaged. Then using An SDS Drill and M16
drill bit Drill one of the rear fixing holes And knock in one
of the M16 Bolts supplied. You can remove the control
Cabinet to gain access to the fixing holes below it, to
Do this remove the M8 nuts fixed at the rear of the
Panel.
Now make sure all cables are through the duct and
Routed where they need to go (e.g mains cable to
The Isolater.) Then after checking the barrier is
Still in line and level proceed to drill and bolt in the
Rest of the fixing bolts. Once all bolts are in make
Sure they are tightened down.
Guide to Physical Installation. (Cont)
U
nwrap the pole very carefully and slide the pole
onto the pole arm adaptor. Using a 6.5mm HSS
Drill bit now drill through both the Pole and the
adaptor at the same time and fit the M6 x 90 Cap
head bolts supplied.
Note - if the pole has boom lights/maglock make
sure you connect these before fitting pole.
5
N
ow the barrier is fully bolted down with the pole on,
Manually wind the barrier in the fully raised and
Lowered positions to ensure everything is correctly
In line.
6
D