2. Display and Keypad Functions

Display

The LCD has a primary and secondary display. 

• The primary display shows the measured pH or Conductivity (µS or mS) reading.
• The secondary display shows the temperature of the reading in °C. 

The display also shows error messages, keypad functions and program functions.

 C

pH

ATC

READY

MEAS

pH

CAL

CON

µ

mS

pH

Temp

HOLD

ERR

2.1

Primary display

CONfirm 
indicator

Secondary display

CALibration
indicator

MEASurement
mode indicator

READY
indicator

HOLD
indicator

ERRor
indicator

Buffer 
indicator

Probe
indicator

Low battery
indicator

pH calibration
mode indicator

Temperature
calibration
mode indicator

Automatic
Temperature
Compensation
indicator

Keypad

The large membrane keypad makes the instrument easy to use. Each button, when
pressed, has a corresponding graphic indicator on the LCD.

ON/OFF

............Powers and shuts off the meter. 

HOLD

..............Freezes the measured reading. To activate, press HOLD while in

measurement mode. To release, press HOLD again.

MODE

..............Selects the measurement parameter (conductivity or pH). 

Press MODE to toggle between pH and Conductivity mode.

CAL/MEAS

......Toggles user between Calibration and Measurement mode. 

• In Conductivity Measurement mode, press

CAL/MEAS to enter Conductivity Calibration mode. 

• In pH Measurement mode, press CAL/MEAS 

to enter pH Calibration mode. 
NOTE:

Temperature calibration is accessible from pH Calibration
mode; see pages 14-15 for instructions.

ENTER

............Press to confirm your calibration values in Calibration mode.

/

▼ 

................Scrolls values up and down in Calibration mode. 

• In pH mode, 

/

▼ 

scrolls through the auto buffer values 

4.00, 7.00 and 10.00.

• In Conductivity and Temperature Calibration mode, 

/

▼ 

lets you

increase or decrease the value incrementally.

5

HOLD

MODE

ON

OFF

CAL

MEAS

ENTER

2.2

MODE

HOLD

ENTER

RANGE

ON

OFF

CAL

MEAS

Содержание 35630-00

Страница 1: ...will be made without charge OAKTON alone will determine if the product problem is due to deviations or customer misuse Out of warranty products will be repaired on a charge basis 13 Return of items Au...

Страница 2: ...ting 19 9 Error Messages 20 10 Specifications 21 11 Accessories 22 23 12 Warranty 24 13 Return of Items 24 2 3 pH Conductivity C Meter HOLD MODE ON OFF CAL MEAS C MEAS pH ATC pH Con 10 Series ENTER 1...

Страница 3: ...nding graphic indicator on the LCD ON OFF Powers and shuts off the meter HOLD Freezes the measured reading To activate press HOLD while in measurement mode To release press HOLD again MODE Selects the...

Страница 4: ...s a notched 6 pin connector to attach the probe to the meter NOTE Do not substitute other probes or electrodes For a replacement probe see the Accessories section page 22 NOTE Keep connector dry and c...

Страница 5: ...bration See section 4 5 on pages 14 15 for temperature calibration Preparing the Meter for Calibration The pH conductivity temperature probe included with this meter is designed for use with this mete...

Страница 6: ...ate the pH standard buffer solution See figure NOTE If using a pH buffer other than pH 7 press the or keys to scroll up or down until the secondary display value is the same as your pH buffer value pH...

Страница 7: ...containers 2 If necessary press the MODE key to select Conductivity Mode The S or mS indicator will appear on the right side of the display 3 Rinse your probe with deionized water then rinse the probe...

Страница 8: ...and the secondary display shows you what the temperature value was initially See figure 4 5 ATC CAL Temp C B A B pH ATC CAL pH pH A 4 Compare the primary display reading to a NIST traceable thermomete...

Страница 9: ...electrode has dehydrated soak it for 30 minutes in OAKTON electrode storage solution or a 2M 4M KCl solution 2 Switch on the meter The MEAS annun ciator appears on the top center of the LCD The ATC i...

Страница 10: ...a Clean probe See Probe Care Maintenance p 18 18 7 Probe Care and Maintenance Under typical operating conditions the probe will need to be replaced every 6 to 12 months In extreme applications the pr...

Страница 11: ...Error Messages LCD Indicates Cause Solution Display Err Unrecognized input Wrong input in Release key Select annunciator from keypad selected mode valid operations depending on mode CAL Err Calibratio...

Страница 12: ...D 00653 04 Electrode storage solution 1 pint bottle Keeps electrode bulb moist for faster more accurate readings Shpg wt 1 1 lbs 510 gms WD 00653 06 Electrode cleaning solution 1 pint bottle Removes b...

Отзывы: