Page 11

Post Installation 

Instructions

With the components installed and wired, please carry out this simple test to ensure that 
the Oaks Smart Access Control System was installed correctly and is fully functional. 

To ensure that there was wiring was done correctly, please press the exit button to see if 
the single door magnetic lock releases for a few seconds. 

If the test is failed

, please reexamine the installation and wiring of the Oaks Smart Access 

Control System.

If the test is successful

, please Install and power on the Rently Keyless Smart Home 

Hub. The hub will automatically connect to the Oaks Smart Access Control system when it 
is powered on. 

Once the light on the back of the hub is a solid blue

, you are all set! 

Содержание Smart Access Control System

Страница 1: ...1...

Страница 2: ...credentials The Smart Access Panel can be used to control any access device that is operated by normally open normally closed signal provided the voltages are compatible The FOBs supported are Mifare...

Страница 3: ...xit Button and Metal Access Control System at ADA recommended height does NOT guarantee ADA compliance Check that all of the components are present Metal Access Control System Exit Button Power Supply...

Страница 4: ...he mounting plate insert screws until it is flush against the desired surface 5 Plug in included cable into the red cable that is attached to the Metal Access Control System 6 Connect the included cab...

Страница 5: ...am Installation Power Supply Controller Specifications No Item Specification 1 Input AC110 V 50Hz 2 Output DC12 50VA 3 Dimension 180mm X78m X 65mm 7in X 3in X 2 5in 4 Weight 1250g 2 75lb 5 Ambient Tem...

Страница 6: ...ey Wiring Diagram for Installation Start by removing 2 silver screws to remove the power supply controller cover There are 4 screw holes on the bottom part of the power supply controller Screw in 2 or...

Страница 7: ...then fix with 4 screws 7 Install the lock plate Make sure the back of lock plate is installed with rubber blanket force and absorb the impact of movement 8 Turn on the power to test it and make sure t...

Страница 8: ...oles for both the door and frame header Ensure that the door opens away from the Maglock In the case of a single door the Maglock is positioned as close as possible to the vertical section of the door...

Страница 9: ...armature plate is not overtightened and that it is installed as shown in the following diagram The armature plate must be free to self align with the door 5 Ensure the armature and magnet are aligned...

Страница 10: ...Wiring Diagram Page 10 Scenario A Oaks Smart Access Control System with Magnetic Lock Scenario B Oaks Smart Access Control System with Electric Strike W ill be coming soon...

Страница 11: ...ly please press the exit button to see if the single door magnetic lock releases for a few seconds If the test is failed please reexamine the installation and wiring of the Oaks Smart Access Control S...

Страница 12: ...re the access panels are assigned to Common Area assets 2 Create a common access community including both the common area assets and the residents home assets 3 Now whenever you set up a resident with...

Страница 13: ...are enabled in the checkboxes 3 Select the fob you want to add and input its number written beneath the barcode into the fob field 4 Enter or randomly generate the 6 digit code you want the staff to h...

Страница 14: ...minutes then click the view all button 5 You can also use the device dropdown to select specific panels you want to review if more than one are attached to the same asset Select that specific device a...

Страница 15: ...tion of creating 24 hour limited codes that only work on a specific common area This can be useful if they are expecting a large number of guests and they don t want to have to let each one in individ...

Страница 16: ...Page 16 How can a resident unlock via the app 1 Log onto the app 2 Select the desired lock to interact with it 3 Tap on unlock to unlock selected lock...

Страница 17: ...t interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and o...

Отзывы: