UM10346_1
© NXP B.V. 2009. All rights reserved.
User manual
Rev. 01 — 2 November 2009
37 of 132
NXP Semiconductors
UM10346
LPC980/982 User manual
5.2 Power-on detection
The Power-on detect has a function similar to the brownout detect, but is designed to work
as power comes up initially to ensure that the device is reset from Power-on. The POF
flag in the RSTSRC register is set to indicate an initial power-up condition. The POF flag
will remain set until cleared by software.
5.3 Power reduction modes
The P89LPC980/982 supports three different power reduction modes as determined by
SFR bits PCON[1:0] (see
Table 19.
BOD interrupt Trip points configuration
BOICFG2
(BODCFG.2)
BOICFG1
(BODCFG.1)
BOICFG0
(BODCFG.0)
BOD Interrupt
Fall
Rise
0
0
0
reserved
reserved
0
0
1
reserved
reserved
0
1
0
2.55V
2.7V
0
1
1
2.85V
3.0V
1
0
0
3.0V
3.15V
1
0
1
3.45V
3.6V
1
1
0
4.15V
4.3V
1
1
1
4.35V
4.5V
Table 20.
BOD Reset and BOD Interrupt configuration
PMOD1/PMOD0
(PCON[1:0])
BOI
(PCON.4)
EBO
(IEN0.5)
EA
(IEN0.7)
BOD
Reset
BOD
Interrupt
‘10’ (power-down) or
‘11’ (total
power-down)
X
X
X
N
N
‘00’ or ‘01’ (normal
or idle mode)
0
X
X
Y
N
1
0
X
Y
N
1
0
Y
N
1
1
Y
Y