Power down
for maximum
rail voltage
Power down or keep the
maximum rail voltage
when rail voltage exceeds
the maximum
gWCT_Params.uCtrlBit.bPowerDownF
orMaxVrail
1
Power down or not
when rail voltage
exceed maximum
value. 1: power
down,
0: keep maximum
“Not Res
Sens” bit for
TX capability
packet
Set “Not Res Sens” bit for
TX capability packet
gWCT_Params.uCtrlBit.bNotResSens
1
Set the value of Not
Res Sens bit for TX
capability packet, 0:
set this bit to 0, 1:
set this bit to 1
Pre-FOD
FOD protection when TX
is in standby state
gWCT_Params.uCtrlBit.bPreFODEnab
le
1
Pre-FOD enable or
disable during
standby state,
1:enable, 0:disable
Duty cycle
control
Duty cycle control when
TX rail voltage is down to
minimum value
gWCT_Params.uCtrlBit.bEnableDutyC
ycleControlForMinRailVol
0
Duty cycle control
enable or disable,
1:enable, 0:disable
BPP
transmitter
TX behaves as BPP
transmitter
gWCT_Params.uCtrlBit.bBPPOnly
0
Only BPP mode
enable or disable. 1:
BPP mode, 0: EPP
mode
8.4. Protection mechanisms
The following table lists the protection that can be implemented.
Table 8.
Protection mechanisms
Protection
Default limits
Variables
Description
Rail voltage
17000 mV
gPROT_Params.wMaxRailVol
Application implemented. If the rail voltage
exceeds the limit, charging is turned off. The
limit value can be changed by
FreesMASTER GUI.
Battery voltage
Min: 8000 mV
Max: 22000
mV
Hysteresis:
1000 mV
gPROT_Params.wMinBatteryVol
gPROT_Params.wMaxBatteryVol
gPROT_Params.wBatteryHystVol
Application implemented. If the battery
voltage exceeds the maximum, the WCT
library stops. When the battery voltage is
lower than the difference between the
maximum and hysteresis, the WCT library
starts. When the battery voltage is lower
than the minimum, the WCT library stops.
When the battery voltage is higher than the
sum of the minimum and hysteresis, the
WCT library starts.
The minimum and maximum limits can be
changed by the FreeMASTER GUI. The
hysteresis value can be changed in
PROT_Init().
Input current
5000 mA
gPROT_Params.wMaxInputCurrent
Application implemented. If the input current
exceeds the limit, charging is turned off. The
limit value can be changed by the
FreeMASTER GUI.