5.2. Real-time application variables monitoring
FreeMASTER enables the monitoring and updating of all the application global variables. In this
application, several key variables are displayed in the scope windows. These variables are divided into
different blocks, as shown in the following figure.
Figure 18. Real-time application variables
•
wct_debug
This block shows the variables used for the GUI command.
•
Library
This block contains the power loss variables, timing variables, coil selection variables, working
parameters, system status, DDM variables, and RX information.
•
HAL
This block contains the ADC raw data and DDM buffer values.
•
NVM
This block lists all NVM parameters. The Q factor sub-block shows the Q factor calibration
constants. The RRQD sub-block shows the quick-removal calibration constants. The FOD
sub-block shows the FOD characterization calibration constants. The normalization sub-block
shows the FOD normalization constants. The analog sub-block shows the rail voltage calibration
constants.
•
LIB PARAMS
This block lists all the parameters used for the WCT library.
•
Command
The command variable is used to stop the WCT, start the WCT, and perform automatic
calibration.