Power
Jetson AGX Xavier Series Product
DG-09840-001_v2.5 | 27
Figure 5-10. Power-OFF to On Sequence Auto Power-On Case
MODULE_POWER_ON
BUTTON_POWER_ON*
CARRIER_POWER_ON
RESET_N
VIN_PWR_ON
POWER_BTN_N
FORCE_SHUTDOWN_N
T_VPWR_ON
T_MPO
T_CPO
ACOK
T_CPO
Table 5-6.
Power-OFF to On Timing Auto Power-On Case
Timing
Parameter
Typical
Units
T_VPWR_ON_AC
Delay from ACOK detected high with main power source
applied to first rail ON (de-bounce only)
20
ms
T_MPO_AC
MODULE_POWER_ON active delay from VIN_PWR_ON
rising edge
80
ms
T_CPO_AC
Maximum allocated delay to CARRIER_POWER_ON active
10
ms