Power
Jetson AGX Xavier Series Product
DG-09840-001_v2.5 | 25
Note: OD – Open-drain. PP = Push-pull.
Figure 5-8.
Power-On Button Circuit
To Module (Pin L54)
POWER_BTN_N
G
D
S
FET
3V3_AO
VIN_PWR_ON
VDD_3V3
G
D
S
FET
CARRIER_POWER_ON
3V3_AO
G
D
S
FET
From Module (Pin L62)
From Power Button
VDDIN_PWR_BAD_N
VDD_5V
3V3_AO
MODULE_POWER_ON
From VIN Loss Detection
& other sources
(Module Pin L55)
3V3_AO
NTS4001
NT1G
0.1uF
4.7k
Ω
10
k
Ω
10
k
Ω
EFM8SB10F8G
VDD
P1.7
P1.6
P1.5
P1.3
P1.2
P2.7_C2D
RST*_C2CK
GND
EPAD
P0.0
P0.1
P0.2
P0.3
P0.4
P0.5
P0.6
P0.7
P1.0
P1.1
10
k
Ω
3V3_AO
10k
Ω
BUTTON_POWER_ON*
ACOK
OVERTEMP_N (FORCE_SHUTDOWN)
SYS_RESET_N
10
k
Ω
10
k
Ω
5V_AO
From Module (Pin L52)
10
0k
Ω
3V3_AO
10
k
Ω
VCC_SRC &
VDD_5V enable
To Module (Pin L61)
To Module (Pin L60)
Used to optinally enable
Auto-Power-On
5.4.2.1
Defined behaviors
For all actions triggered by
BUTTON_POWER_ON*
, there will be a de-bounce time before
triggering any output signal. All timings below are referenced from AFTER the de-bouncing.
Therefore, a “0 ms” value indicates that the signal should start right after de-bounce. De-
bounce time is 20 ms.
5.4.2.2
Power OFF -> Power ON (Power Button Case)
Power button press use case: User presses the Power Button briefly, and the MCU sends the
power enable signals to the module (
VIN_PWR_ON
) and to the PMIC on the module
(
MODULE_POWER_ON
). The signal representing the power button to Jetson AGX Xavier
(
POWER_BTN_N
), will have the same (brief) duration of the Power Button input to the MCU. Once
the power button is pressed, the power OK input (ACOK) is ignored, as the power ON sequence
is already initiated by the power button.