MCH36 Open Diesel (Kubota)
www.nuvair.com Page | 32
MCH36 Open Diesel (Kubota)
18.0 Start-Stop Operation Quick start Guide
1.
Check Oil Level in Engine
2.
Check Oil Level in Compressor
3.
Turn the Manual Bypass Valve to the Start position
4.
Turn Key to Start Position
a.
If engine does not start after 10 seconds of cranking; turn off key and rest starter
for 30 seconds.
5.
Once Engine Starts, turn the Manual Bypass Valve to the Run position
6.
Adjust Throttle to desired RPM
7.
Check Gauges for proper Stage Pressure
a.
Oil 14.5 psi Min
b.
1
st
Stage 45-60 psi
c.
2
nd
Stage 230-290 psi
d.
3
rd
Stage 940-1200 psi
e.
4
th
Stage 5000 psi Max
8.
To Stop Compressor reduce RPM
9.
Turn Key to Off
10.
Check that Automatic Drains are Open and Drain All Moisture