If the compressor is located in an area where there is high humidity and high heat, the life
of all Filtration Elements may be as little as 35% of rated operating capacity. Check the
Compressor manual and Appendix for details on Filter Element Life Factors.
13.1 Temperature effect on filter life.
The active carbon filters are classified as special waste once the compressor has been
used to make air: they must be disposed of in compliance with the anti-pollution standards
in force.
The Condensate tank must be drained at the end of every working day or every 2 to 3 hours
of operation. The Compressor Condensate must be drained every 5-10 minutes of
operation.
13.2 Condensate Discharge
An outflow of condensate water with lubricating oil is normal during refills: the quantity will depend
on the level of humidity in the air. The condensate must be disposed of as per your local “Waste
disposal” rules.
To Drain the Condensate Tank:
•
Open the Manual bleed valve pictured right and drain
into a portable container for disposal.
The Condensate Tank must be drained daily or
every 6 working hours. You may run a hose from
the condensate tank into a larger receiver and
leave the ball valve in the open position.
•
Manually Open Auto Drain Valves each day
to check for Condensate and that the
Auto Drains are functioning properly.
Filter replacement frequency calculation table
Temperature
(°F)
Temperature
(°C)
Filter duration
(hours)
Filter duration
(hours)
MCH30
MCH36
104
40
27
23.1
95
36
31.5
31
86
30
39.5
39.8
80
27
45
44.25
68
20
70
68.1
50
10
126
122.5