MCH36 Open Diesel (Kubota)
www.nuvair.com Page | 20
MCH36 Open Diesel (Kubota)
During bottle refill those not involved in the refill procedure must maintain a safety distance
of at least 9 feet (3 meters). Also, it is forbidden to disconnect the hoses from the fittings or
the refill tap while the machine is under pressure.
Should bottles show evident signs of internal or external corrosion, do not refill them even
if they have been tested.
Use only tested bottles (as proven by a test stamp and/or certificate). The working and
bottle refill pressures are shown on the bottles themselves. It is forbidden to refill them at a
pressure greater than that indicated.
11.0 Maintenance
11.1 About Maintenance
To obtain the best possible performance from the compressor and ensure a long working
life for all its parts it is essential that personnel follow the use and maintenance instructions
with extreme diligence. It is thus advisable to read the information below and consult the
manual every time an inconvenience arises. For further information please contact Nuvair
Nuvair
Address:
Phone
: +1 805 815 4044
1600 Beacon Place
Email:
Oxnard, California 93033, USA
11.2 General
•
Proper preservation of the compressor requires thorough cleaning.
•
This type of refill station, designed and built according to the most advanced technological
criteria, requires only minimum preventive and routine maintenance.
•
Before carrying out any maintenance tasks, run checks and/or controls on the compressor,
switch off the compressor, remove the plug from the mains socket.
•
The residual pressure present in the compressor and all lines must be released.
•
During disassembly and re-assembly of the compressor, always use suitable
wrenches/tools so as not to damage the relevant components.
•
Loosen stiff parts with a copper or plastic mallet.
•
When refitting parts make sure they are clean and lubricated sufficiently.
•
Compressor maintenance tasks must only be carried out by authorized personnel and
recorded on page 31 Maintenance Log of this manual.
11.3 Unscheduled Work
Involves repairs and/or replacement of the mechanical parts of one or more compressor
components, this work normally needs to be done after some years of use. If substantial
modifications are made, the manufacturer cannot be held liable for any dangers that might
Содержание Coltri MCH 36 Electric
Страница 1: ...User Manual MCH36 Diesel Open Kubota Rev 07 18...
Страница 2: ......