MCH36 Open Diesel (Kubota)
www.nuvair.com Page | 27
MCH36 Open Diesel (Kubota)
13.0 HP Compressor Filtration Active Carbon Filters / Molecular Sieve
The HP Compressor comes standard with Triplex filtration, utilizing a single Filter Element. Do
NOT use any substitute. Change filter element every 90,000 cubic feet of air pumped. If the
compressor system is operated in high humidity and/or high temperature, filter element must be
changed more often. See 13.1 for details on filter element life factors.
1) Shut down the Compressor System
2) Open Manual Bleed Drain Valve to drain pressure. Leave valve open.
3) Unscrew the Filter Canister Cap.
4) Remove expended Element from Filter Canister.
5) Install New Element. Place pressure on element to seat.
6) Reinstall Canister Cap.
7) Close Manual Condensate Valve.
*Note: Pictures are for illustration purposes, not of the
actual unit.
Be sure that all pressure has been relieved from the system prior to opening any filtration
canister. Failure to vent pressure from the system prior to opening the canister can lead to
serious personal injury or death. Difficulty turning the filter cap may indicate there still is
pressure in the filter canister.
5
4
3
Filter Canister Caps
Condensate
Tank
Manual Bleed
Drain Valve
HP Filter Replacement parts:
X65247