NuTone QTNLEDA Скачать руководство пользователя страница 3

Page 3

MODEL  QTNLEDA

4.  Connect electrical wiring.

 

Run 120 VAC house wiring to installation location. Use 
proper UL approved connector to secure house wiring to 
wiring plate. Connect wires as shown in wiring diagrams.

CONNECT WIRING

2.  Attach 

damper/duct 

connector.

Snap damper / 

duct connector 

onto housing. 

Make sure 

connector is flush 

with top of housing 

and damper flap 

falls closed.

3.  Install 

6-inch or 

4-inch round 

ductwork.

Connect 6-inch 

or 4-inch round 

ductwork to 

damper / duct 

connector or 

reducer. Run 

ductwork to a roof 

cap or wall cap. 

Tape all ductwork 

connections to make them secure and air tight.

1b. Mount housing anywhere between 

trusses, joists, or 

I

-joists using hanger 

bars.

 

Sliding  hanger  bars  are  provided  to  allow  for  accurate 

positioning of housing anywhere between framing. They can 

be used on all types of framing (

I

-joist, standard joist, and 

truss construction) and span up to 24”.

Attach  the  MOUNTING  CHANNELS  to  the  housing  using 

the SCREWS supplied. Make sure TABS face “up” as shown. 

Use the set of channel mounting holes (marked “STD”) to 

mount the housing flush with the bottom of the drywall. Use 

the other set of holes (not marked) to mount the housing 

flush with the top of the drywall.

HANGER

BAR (4)

SCREWS (4)

TAB

 

Extend HANGER BARS to the width of the framing.

 

Hold  ventilator  in  place  with  the  hanger  bar  tabs  wrapping 

around the BOTTOM EDGE OF THE FRAMING.

 

NAIL ventilator to framing or fasten with screws (not provided) 

through HOLES near nails.

 

*

 To ensure a noise-free mount: Secure hanger bars together 

with  SCREWS  or  use  a  pliers  to  crimp  mounting  channels 

tightly around hanger bars.

HOLE FOR OPTIONAL 

SCREW MOUNTING (4)

STD

MOUNTING

CHANNEL (2)

NAIL (4)

BOTTOM EDGE 

OF FRAMING

*

 

SCREW (2)

Содержание QTNLEDA

Страница 1: ...2 This product is designed for installation in ceilings up to a 12 12 pitch 45 degree angle Duct connector must point up DO NOT MOUNT THIS PRODUCT IN A WALL 3 To avoid motor bearing damage and noisy...

Страница 2: ...re between trusses using hanger bars INSTALL HOUSING DUCT 1a Mount housing to joist or I joist Use a pliers to bend housing TABS out to 900 Hold housing in place so that the housing tabs contact the b...

Страница 3: ...ning of housing anywhere between framing They can be used on all types of framing I joist standard joist and truss construction and span up to 24 Attach the MOUNTING CHANNELS to the housing using the...

Страница 4: ...its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS TUBES HALOGEN AN...

Страница 5: ...lafond dont la pente n exc de pas 12 12 45 degr s Le raccord de conduit doit pointer vers le haut CE PRODUIT NE PEUT PAS TRE POS DANS UN MUR 3 Pour viter d endommager les roulements de moteur de d s q...

Страница 6: ...DU PLAFOND GRILLE SOLIVE DU PLAFOND BO TIER Bo tier mont n importe o entre des solives l aide des barres de suspension Bo tier mont n importe o entre des fermes de toit l aide des barres de suspensio...

Страница 7: ...ural ou de toit tanchez tous les joints avec du ruban adh sif 1b Fixez le bo tier n importe o entre les fermes solives ou solives en I avec les barres de suspension Les barres de suspension fournies p...

Страница 8: ...stipul pour la garantie expresse Certains territoires ou provinces interdisant de limiter la dur e d une garantie tacite la limitation ci dessus peut ne pas s appliquer votre situation L OBLIGATION PO...

Страница 9: ...de materiales o vapores peligrosos o explosivos 2 Este producto est dise ado para instalarse en cielos rasos con una pendiente de hasta 12 12 en un ngulo de 45 grados El conector de conductos debe ap...

Страница 10: ...L DEL CIELO RASO REJILLA VIGUETA DE CIELO RASO CUBIERTA Montaje de la cubierta en cualquier parte entre las viguetas por medio de barras de suspensi n Montaje de la cubierta en cualquier parte entre a...

Страница 11: ...uctura Estas barras se adaptan a toda clase de estructuras construcciones de viguetas I viguetas est ndares y armaduras y se extienden a un m ximo de 24 pulg 61 cm Fije los CANALES DE MONTAJE a la cub...

Страница 12: ...ndadas La duraci n de una garant a impl cita se limita al per odo de tres a os como se especifica para la garant a expl cita Algunos estados no permiten limitaciones en cuanto al tiempo de vencimiento...

Отзывы: