background image

Operating Instruction and Documentation

                                                                         UNI-LIFT 5000 CLT / Plus

- 49 -

Function button:

<*> Back to the position-ad (2).
<0> ... < 9 > password input

4.2 Service-Menu

Dialed menu-point becomes through > < marked

Function button:

< * > next menu-point dials
< #> menu-point activates
The menu-point becomes >zurück < activated jumps back this to the position-ad.

4.3 STEERED

Both axes of the lift can be driven individually over the function " GESTEUERT ". The
driven axis becomes over “* “marks and demarcates and after it over „#“activates. This
function can be used only in the disturbance-case!
controlled operation - axis 1 active

The controlled business over the ad-functions is only possible if the dip-switch stands 5 on
the “Achscontroller” on “ON”!
If the dip-switch 5 is standing on “OFF”, the axe drives over the dip-switch-attitude,
independently from the ad-function.

Over the buttons  < 1 >, < 2 > is dialed the axes, the steered procedures should become.
The dialed axes become on the ad through *X * marks.

If the button < lifting > or < lowering >  was pressed afterwards, only the select axe can
moved.

! The installation can become destroyed.

Function button:

< * > Abortion and return into the service-menu (4.2)

< l > axe 1 activates / deactivates
< 2 > axe 2 activates / deactivates

>Gesteuert<
Achse nullen
Hubhöhe
zurück

*1* 50.3

2

 

0.0

Содержание UNI-LIFT 5000 CLT PLUS

Страница 1: ...ating Instruction and Documentation Serial number Nussbaum Hebetechnik GmbH Co KG Korker Stra e 24 D 77694 Kehl Bodersweier Tel 49 0 7853 8990 Fax 49 0 78 53 87 87 E mail info nussbaum lifts de http w...

Страница 2: ...the 2 rails main lift 21 5 6 Manual equalisation of the lift 21 6 Troubleshooting 22 6 1 Driving on an obstacle 23 6 2 Emergency lowering of the main lift wheel free lift 24 6 3 Reset the main lift a...

Страница 3: ...s to be observed In addition to the safety remarks of the instructions for use the regulations and instructions being valid at the place of operation have to be considered Obligations of the operator...

Страница 4: ...rt components as mentioned in the instructions for use are to be adhered These works must only be carried out by expert personal After maintenance and repair works loose screw connections must always...

Страница 5: ...the safety was checked and the lift was started The installation was effected from the operating authority competent please delete as applicable The safety of the automotive lift was checked from the...

Страница 6: ...e lift was started The persons below were introduced after the installation of the automotive lift The introduction was carried out from an erector of the lift manufacturer or from a franchised dealer...

Страница 7: ...the lift They are called experts and competent persons in this document Experts are persons for example self employed engineers experts which have received instruction and have experience to check an...

Страница 8: ...cing vehicles It is not allowed to carry persons with the lift It is not allowed to climb on the lift or on the vehicle It s not allowed to install the standard automotive lift in a hazardous location...

Страница 9: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 9 page for notice...

Страница 10: ...Hydraulic pressure main lift ca 240 bar with load Hydraulic pressure wheel free lift ca 215 bar with load pressure relief valve main lift ca 260 bar pressure relief valve unlocking cylinder ca 35 bar...

Страница 11: ...th knowledge and experience who has joined a special training of the lift manufacturer Erectors of the manufacturer and its retailers are competent persons CE STOP main lift and wheel free lift When r...

Страница 12: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 12 3 3 Datasheet...

Страница 13: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 13...

Страница 14: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 14...

Страница 15: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 15...

Страница 16: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 16...

Страница 17: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 17...

Страница 18: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 18...

Страница 19: ...is lift Position the polymer supports as described of the vehicle manufacturer under the vehicle Version with wheel free lift The correct position of the polymer pads has to be checked after the vehic...

Страница 20: ...mmediate area of the lift or on the lift Lower the vehicle to the working height or until the platform reaches the lowest point press the button lowering Before the lift reaches the lowest position it...

Страница 21: ...est position 5 5 Equalisation of the 2 rails main lift Press button Equalize at the operation unit The rails of the main lift equalize It is not possible to equalize the wheel free lift with this butt...

Страница 22: ...ed on the following pages If the cause of trouble cannot be found please call the technical service Problem Motor does not start Potential causes no power supply main switch is not engaged fuse defect...

Страница 23: ...the control box Switch off the main switch and wait 5 sec Hold the reset button Switch on the main switch and wait 5 sec Hold the reset button Let go off the reset button Move all the Dip switch on p...

Страница 24: ...switch and wait 5 sec Hold the reset button Let go off the reset button Dip switch 5 stays in on position Move the Dip switch 7 on position off On the computer board must now three diodes lighten perm...

Страница 25: ...y and to lower the lift into its lowest position so that the vehicle can be driven off Preparation to the emergency lowering 1 Switch off the main switch and safe it lock it The emergency lowering can...

Страница 26: ...ears After finishing the emergency lowering the set screws and the locknuts must be brought back into the original position otherwise a malfunction of the lift may occur Do not use the lift until defe...

Страница 27: ...Condition The security system is not locked The double seat valves are pressed see pic 5 pos X Open the locknut N1 N2 red of the hydraulic block Turn carefully maximal one rotation anticlockwise the e...

Страница 28: ...o life and danger of damages 6 3 Reset the main lift after an emergency lowering Only when the lift is in the lowest position is the reset of the lift possible An access on the Dip Switch is only allo...

Страница 29: ...Company Clean and lubricate the moving parts of the lift hinge bolts sliding pieces sliding surfaces grease with a multipurpose lipid example Auto Top 2000 LTD Agip Grease the lubricate nipples with...

Страница 30: ...e cleanness of the workshop and location of the lift The degree of the dirt is dependent on the season of the weather conditions and the ventilation of the workshop Under bad circumstances it is neces...

Страница 31: ...ing on carrying parts an extraordinary security check must be performed by an expert This manual contains form with a schedule for the security checks Please us the adequate form for the security chec...

Страница 32: ...ttention only by 3 phase supply 9 Press the button lifting until the lift is on a height of approx 10 cm 10 Press the button lowering until both platforms are in the lowest position and the acoustic s...

Страница 33: ...Tighten the Liebig dowels with the dynamometric key M 80Nm Each dowel must be tightened with the demanded torque Otherwise the normal function of the lift can not be guaranteed Observe the regulation...

Страница 34: ...Remove the cover of the hydraulic tubes Loose the dowels Lower the lift in the lowest position Loose the plug of the power supply If necessary loose the hydraulic hoses only on the operating unit If n...

Страница 35: ...loor pavement or tile surface Table to pic 8 Liebig dowels Dowel type B20 75 B20 100 Drilling depth a 115 140 Min anchorage depth b 85 85 Thickness of concrete c 180 180 Diameter of bore d 20 20 Thick...

Страница 36: ...g dowels Dowel type B20 100 B20 125 B20 135 B20 175 Drilling depth a 140 165 175 215 Min anchorage depth b 85 85 85 85 Thickness of concrete c 180 180 180 180 Diameter of bore d 20 20 20 20 Thickness...

Страница 37: ...ing Condition piston rod Condition of the covers Closeness of the hydraulic system Level of hydraulic oil Condition hydraulic hoses Condition electrical wires Function test with vehicle Function equal...

Страница 38: ...tion piston rod Condition of the covers Closeness of the hydraulic system Level of hydraulic oil Condition hydraulic hoses Condition electrical wires Function test with vehicle Function equalisation o...

Страница 39: ...tion piston rod Condition of the covers Closeness of the hydraulic system Level of hydraulic oil Condition hydraulic hoses Condition electrical wires Function test with vehicle Function equalisation o...

Страница 40: ...tion piston rod Condition of the covers Closeness of the hydraulic system Level of hydraulic oil Condition hydraulic hoses Condition electrical wires Function test with vehicle Function equalisation o...

Страница 41: ...tion piston rod Condition of the covers Closeness of the hydraulic system Level of hydraulic oil Condition hydraulic hoses Condition electrical wires Function test with vehicle Function equalisation o...

Страница 42: ...tion piston rod Condition of the covers Closeness of the hydraulic system Level of hydraulic oil Condition hydraulic hoses Condition electrical wires Function test with vehicle Function equalisation o...

Страница 43: ...tion piston rod Condition of the covers Closeness of the hydraulic system Level of hydraulic oil Condition hydraulic hoses Condition electrical wires Function test with vehicle Function equalisation o...

Страница 44: ...tion piston rod Condition of the covers Closeness of the hydraulic system Level of hydraulic oil Condition hydraulic hoses Condition electrical wires Function test with vehicle Function equalisation o...

Страница 45: ...tion piston rod Condition of the covers Closeness of the hydraulic system Level of hydraulic oil Condition hydraulic hoses Condition electrical wires Function test with vehicle Function equalisation o...

Страница 46: ...elding Condition piston rod Condition of the covers Closeness of the hydraulic system Level of hydraulic oil Condition hydraulic hoses Condition electrical wires Function test with vehicle Function eq...

Страница 47: ...on of the lift Al A2 position value of the 2 axes Step during the business a mistake on the axis becomes with the mistake through E in the position ad marked The ad changes between the position ad and...

Страница 48: ...y for these two cases this operating mode of the lift is intended Is not allowed to activate these functions if the lift has the normal function The functions of the service operation can be activated...

Страница 49: ...n the disturbance case controlled operation axis 1 active The controlled business over the ad functions is only possible if the dip switch stands 5 on the Achscontroller on ON If the dip switch 5 is s...

Страница 50: ...nstallation can become destroyed Function button Abortion and return into the service menu 4 2 axes becomes on zero favored 4 5 Altitudes restricts The maximum lifting of the lift can be restricted ov...

Страница 51: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 51 Hydraulic diagram without wheel free lift...

Страница 52: ...0 8 hydraulic block 06 605A 01 01 DB1 pressure relief valve 155211 DB2 pressure relief valve unlocking cylinder 155211 M1 M4 measuring connection 155470 VW1 proportional valve WEP06DA01B0240S VW2 pro...

Страница 53: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 53 Hydraulic diagram with wheel free lift...

Страница 54: ...e relief valve 155211 DB2 pressure relief valve unlocking cylinder 155211 M1 M4 measuring connection 155470 VW1 proportional valve WEP06DA01B0240 VW2 proportional valve WEP06DA01B0240 VW3 4 2 way valv...

Страница 55: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 55 Electric diagram without wheel free lift...

Страница 56: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 56 Electric diagram with wheel free lift...

Отзывы: