Operating Instruction and Documentation
UNI-LIFT 4000
- 41 -
• Drive vehicle over the lift, longitudinal axes on line of the lift.
• Block the vehicle against rolling, put into gear.
• Check the dangerous places of the lift and be sure that there are no objects or people in the
immediate area of the lift or on the lift.
• Switch on the control system; main switch on position ”1” (see pic.1)
• Raise the lift. Press the button „lifting“.
• Lift the vehicle on the working height. Press the button „lifting“ .
• Observe the complete lifting procedure.
5.2 Lowering the vehicle
• Check the dangerous places of the lift and be sure that there are no objects or people in the
immediate area of the lift or on the lift.
• Lower the vehicle to the working height or until the platform reaches the lowest point; press
the button „lowering“ .
• Observe the complete lowering procedure.
• Before the lift reaches the lowest position, it stops (CE-STOP).
Let off the „lowering”. Control the dangerous places. Press the button again. You hear an
acoustic signal until the lift reaches the lowest position.
• Drive the vehicle out of the lift if the lift is in the lowest position.
• Observe the complete lowering procedure.
5.3 Lowering into the ratchet for wheel alignment
• Before carrying out the wheel alignment procedure, the lift must be lowered into the ratchet.
• Raise the lift on the working height.
• Press the button „lowering into the ratchets“.
• Press the button until the hydraulic system is without pressure and both green lights at the
operating unit are on.
In case the even surface of the workshop floor is not guaranteed, wrong data of the
wheel alignment are possible. Before, levelling the automotive.
• After the wheel alignment procedure, press the button „lifting” until the ratchets are
unlocked.
• After it, lower the lift onto the working height.
5.4 Equalisation the platforms
The automotive-lift is equipped with an automatic equalisation system of the platforms. Every
time when the lift is set into the ratchets for performing wheel-alignment, the slave side will be
lowered to the level of the master side if the two sides are unequal in height. Every time the
UNI-Lift is lifted from the lowest position the slave side will be lifted to the level of the master
side. The lift is equipped with a photoelectric barrier that supervises the ganging of the two rails.
If the lift is used for a certain time without being set into the ratchets or reaching the lowest
position an unequal level of the two rails might occur which is caused by normal operating. The
Содержание UNI-LIFT 4000 MB
Страница 4: ...Operating Instruction and Documentation UNI LIFT 4000 4...
Страница 5: ...Operating Instruction and Documentation UNI LIFT 4000 5...
Страница 6: ...Operating Instruction and Documentation UNI LIFT 4000 6...
Страница 7: ...Operating Instruction and Documentation UNI LIFT 4000 7...
Страница 8: ...Operating Instruction and Documentation UNI LIFT 4000 8...
Страница 9: ...Operating Instruction and Documentation UNI LIFT 4000 9...
Страница 16: ...Operating Instruction and Documentation UNI LIFT 4000 16 2 5 Declaration of conformity...
Страница 18: ...Operating Instruction and Documentation UNI LIFT 4000 18 3 3 Datasheet...
Страница 19: ...Operating Instruction and Documentation UNI LIFT 4000 19...
Страница 22: ...Operating Instruction and Documentation UNI LIFT 4000 22...
Страница 23: ...Operating Instruction and Documentation UNI LIFT 4000 23 3 4 Hydraulic diagram drawing...
Страница 25: ...Operating Instruction and Documentation UNI LIFT 4000 25 3 5 Electrical diagram drawing...
Страница 26: ...Operating Instruction and Documentation UNI LIFT 4000 26...
Страница 27: ...Operating Instruction and Documentation UNI LIFT 4000 27...
Страница 28: ...Operating Instruction and Documentation UNI LIFT 4000 28...
Страница 29: ...Operating Instruction and Documentation UNI LIFT 4000 29...
Страница 30: ...Operating Instruction and Documentation UNI LIFT 4000 30...
Страница 31: ...Operating Instruction and Documentation UNI LIFT 4000 31...
Страница 32: ...Operating Instruction and Documentation UNI LIFT 4000 32...
Страница 33: ...Operating Instruction and Documentation UNI LIFT 4000 33...
Страница 34: ...Operating Instruction and Documentation UNI LIFT 4000 34...
Страница 35: ...Operating Instruction and Documentation UNI LIFT 4000 35...
Страница 36: ...Operating Instruction and Documentation UNI LIFT 4000 36...
Страница 37: ...Operating Instruction and Documentation UNI LIFT 4000 37 3 7 Electrical plug connection...