Operating Instruction and Documentation
Sprinter NT
- 23 -
• If the lift reached the lowest position, remove the polymer-supports and drive the
vehicle out of the lift.
• After the emergency lowering close the screws N1 and N2 and the locknuts.
• Do not work with the lift until the faulty parts are exchanged. Call the service-
partner.
Switch off the main switch and lock it. Do not work with the lift until the faulty
parts are exchanged.
7. Maintenance
A regular service has to be performed every three months by the lifts operator
according to the following schedule. If the lift is in continuous operation or dirty
environment, the maintenance rate has to be increased.
During daily operation the lift has to be watched carefully for its correct function.
In case of any malfunction the technical service of the retailer has to be in formed.
7.1 Inspection and Maintenance of Nussbaum lifts
Nussbaum lifts have been designed and manufactured for longevity and safe operation.
Proper installation and operation, regulär inspections and ensuing preventative
maintenance by authorized personnel and product care, are the key to operators safety,
product reliability, low overall repair costs, qualified warranty claims and finally,
longevity of the lift. Our lifts are German TÜV and European CE certified and meet or
surpass the safety standards of the countries in which we seil. European regulations for
instance, oblige inspection by qualified personnel, every 12 months during the life span
of the lift.
Whatever the regulations are in a given country, the following are the
minimum, requirements regarding the maintenance of Nussbaum lifts.
1.
Product care. On an daily/weekly basis by lift operator
Always contact qualified service personnel whenever there is a safety issue. Check
for anomalies at all times in particular after electrical power failure or flooding of the
shop floor (check sealing of the canister of in-ground TOP lifts). Execute equalization
procedure of lifts with master/slave system (SPRINTER- and UNI-LIFTS). Check for
leaky and kinked pipes and hoses. Clean the lift and the floor with a non-aggressive
detergent. Prevent corrosion by oiling metallic parts or paint retouch. Check filters,
grease/lubrication needs and air pressure. Check condition of lifting pads/polymer
supports.
2.Inspection. At least once a year by qualified technician
Safety related:
•
Check the proper functioning of all mechanical, electrical, hydraulic
and pneumatic safety locking functions