Operating Instruction and Documentation
Sprinter NT
- 10 -
3. Technical Information
3.1 Technical ratings
Capacity:
3000 kg
Load distributation:
3:2 in or against drive-on direction
Lifting time:
approx. 7 sec.
Lowering time:
approx. 6 sec.
Line voltage:
3 x 400 Volt , 50Hz
Power rating:
3 kW
Motor speed:
3000 rotation/min
Pump capacity:
3 ccm/revolution
Hydraulic pressure:
approx. 270 bar
Pressure relief valve:
approx. 300 bar
Oiltank:
approx. 14 litre - viscosity 32 cst.
Sound level:
≤
75 dBA
Connection by customer (standard)
3~/N+PE, 400V, 50 Hz
with fuse T16A
(Pay attention to the tension of your state)
3.2 Safety device
1. Pressure relief valve
Overprint-safety of the hydraulic system
2. Holding valve
safety device against unintentional lowering
3. Lockable main switch
safety device against unauthorized operation
4. Foot protector
safety device against squeeze
5. Two independent cylinder system (master and slavesystem)
Safety device against unintentional lowering